Installer Manual
Installation of dual system
The installation of a EFIT™ 850 with 2 roof systems or 2 ground systems has been se-
lected .
It is
mandatory
that no sensors or only sensors for
System A
are connected to the the
EFIT™ 850 before power up . Sensors for
System B
must be connected to the EFIT™ 850
during the installation steps . Connection of the sensors during installation can either
be done using a switch on the DIN-rail or just connect sensor bus of
System B
to the
already connected sensor bus of
System A
.
The first installed system
(System A)
is using the output
System A
.
The second installed system
(System B)
is using the output
System B
.
If sensors for
System A
are not connected - do it now!
Press
or wait…
System is being scanned to find type of connected
sensors…
Select system type
Wait until correct number of sensors for
System A
is
found .
Press
when all sensors for
System A
are found…
System A
is installed…
Connect sensors for
System B
.
Press
or wait…
System is being scanned to find type of connected
sensors…
Select system type
Connect sensors:
System A
System A
Scanning...
System type:
Ground
1 Ground sensor
found.
Accept?
System A
Installed!
Connect sensors:
System B
System B
Scanning...
System type:
Ground
Summary of Contents for EFIT 850
Page 1: ...1 Installation and user manual EFIT 850 controller GB DAS ...
Page 24: ...24 Sensor added If the user selected a new sensor to add the sensor is added Installer Manual ...
Page 29: ...Appendix 29 Installer menu _ View statistics Change system Installer menu Appendix A ...
Page 31: ...Appendix 31 View statistic View statistics Appendix A ...