18
Installer Manual
Connect sensors:
System A
System A
Scanning...
System type:
Roof
1 Roof sensor
found.
Accept?
Installation of combi system
The installation of a EFIT™ 850 with 1 roof system and 1 ground system has been se-
lected .
It is optional if the sensors are connected to the EFIT™ 850 before power on or during
the installation .
The first installed system (
System A
) is using the output
System A
.
The second installed system (
System B
) is using the output
System B
.
It is freely selectable if System A should be the roof or ground system . However it is
preferable that System A is the roof system, since System A is shown on the upper line
of the display . Please refer to the description of the Display and Combined view in the
user manual .
If sensors for
System A
are not connected - do it now!
Press
or wait…
System is being scanned to find type of connected
sensors…
Select system type: Roof
(if roof system is preferred as
System A
)
Wait until correct number of sensors for
System A
is found .
Press
when all sensors are found…
System A
is installed…
If sensors for
System B
are not connected - do it now!
Press
or wait…
System is being scanned to find type of connected
sensors…
Select system type: Ground
(if ground system is preferred as
System B
)
Connect sensors:
System B
System B
Scanning...
System type:
Ground
System A!
Installed
Summary of Contents for EFIT 850
Page 1: ...1 Installation and user manual EFIT 850 controller GB DAS ...
Page 24: ...24 Sensor added If the user selected a new sensor to add the sensor is added Installer Manual ...
Page 29: ...Appendix 29 Installer menu _ View statistics Change system Installer menu Appendix A ...
Page 31: ...Appendix 31 View statistic View statistics Appendix A ...