5.9. Open-window function
eco features an Open-window function, which
closes the valve if the room temperature is falling
dramatically, thus reducing the heat loss.
The heat is turned off for up to 30 minutes, before eco
returns to its original settings.
When Open-window has been activated, the function
is quarantined for 45 minutes.
Note! Be aware that the Open-window function will be
affected, if curtains or furniture are covering eco,
preventing it from detecting the decreasing temperature.
6. Safety precautions
The thermostat is not intended for children and must not be used as a toy.
Do not leave packaging materials where children may be tempted to play with them, as this is
extremely dangerous.
Do not attempt to dismantle the thermostat as it contains no user-serviceable parts. If error code
E1, E2 etc. is shown in the display or other defects appear, please return the thermostat to the
distributor.
7. Disposal
The thermostat must be disposed of as electronic waste.