background image

Installation guide

Single/Dual inclination sensor 

DST X730

09

8R

00

07

09

8R

00

07

© Danfoss | DCS (im) | 2019.04

AN30144792979601-000101 | IC.PD.P20.EA.2Q | 1

TILT DIRECTION

M12 VERSION - single axis Z

ELECTRICAL CONNECTIONS

M12 VERSION - single axiz Z

CONNECTIONS

1. + SUPPLY
2. OUTPUT Y
3. GROUND
4. OUTPUT X
5. n.c.

CABLE VERSION - dual axis XY

CONNECTIONS

White: + SUPPLY
Yellow: GROUND
Grey: OUTPUT X
Blue: OUTPUT Y
Pink: n.c.
Green: n.c.
Brown: n.c.

DST X730

TOP SINGLE/DUAL AXIS
INCLINOMETER (XY/360°)

Danfoss A/S 6430 Nordborg Denmark 
www.danfoss.com

WARNINGS AND SAFETY

Although all of the information in this manual has
been carefully checked, Danfoss A/S assumes no 
liability regarding the presence of any errors or regarding 
damage to property and/or harm to individuals due to any improper use 
of this manual. Danfoss A/S also reserves the right to make changes to the 
contents and form of this manual and to the characteristics of the devices 
illustrated at any time and without prior warning.
The installation of the devices illustrated in the manual must be carried out by 
qualified technicians in compliance with the laws and standards in force and 
in agreement with the instructions contained in the manual.
The system should be only used in accordance with
the expected protection.
The sensor must be used in accordance with the environmental
features and performance of the instrument.

            LOAD CONDITIONS

+0.5VDC…+4.5 VDC output (powered at 10...36VDC) and 0...10 VDC out-

put (powered at +11…36 VDC): apply a load resistance > 100kΩ

+0.5 VDC…+4.5 VDC output ( powered at +5 VDC) maximum allowed 

load resistance is >10 kΩ

+4...20 mA output (powered at < +15..36 VDC) maximum allowed load 

resistance is 200Ω

+4...20 mA output (powered at > +15..36 VDC) maximum allowed load 

resistance is 500Ω

MOUNTING

Mount the sensor using M5 screws in nonmagnetic stainless 

steel: eg AISI 316 or brass (not included).

It is mandatory to use conical spring washer M5 DIN 6796 A2 

- 3 pcs. (included).

ELECTROMAGNETIC COMPATIBILITY, VIBRATION, SHOCK – 

REFERENCE STANDARD:

Electromagnetic compatibility according to Directive 2004/108/CE

Vibrations 20g between 10Hz ... 2000 Hz EN 60068-2-6

Shock pulse on 3 axes, 50g 11 ms EN 60068-2-27

CABLE VERSION - dual axis XY

CAN CONNECTIONS

1. n.c 
2. + SUPPLY
3. GROUND.
4. CAN-H.
5. CAN-L

CONEC connector

M12 x 1 5 pole 43-01090

CAN CONNECTIONS

White: + SUPPLY
Yellow: GROUND
Grey: CAN-H
Blue: CAN-L
Pink: n.c.
Green: n.c.
Brown: n.c.

Mandatory use conical spring 
washer
M5 DIN 6796 A2 (3 pcs included)

Summary of Contents for DST X730

Page 1: ...s in force and in agreement with the instructions contained in the manual The system should be only used in accordance with the expected protection The sensor must be used in accordance with the environmental features and performance of the instrument LOAD CONDITIONS 0 5VDC 4 5 VDC output powered at 10 36VDC and 0 10 VDC out put powered at 11 36 VDC apply a load resistance 100kΩ 0 5 VDC 4 5 VDC ou...

Page 2: ...6VDC und Ausgang 0 10VDC Versorgung 11 36VDC empfohlener Lastwiderstand 100 kOhm Ausgang 0 5VDC 4 5VDC Versorgung 5VDC empfohlener Lastwider stand 10 kOhm Ausgang 4 20 mA mit Versorgung 15 36VDC max zulässiger Last widerstand 200 Ohm Ausgang 4 20 mA mit Versorgung 15 36VDC max zulässiger Last widerstand 500 Ohm LASTBEDINGUNGEN MONTAGE Zum Befestigen des Sensors M5 Schrauben aus unmagnetischem Edel...

Page 3: ...c et sortie 0 10Vcc avec alimentation 11 36Vcc résistance de charge recommandée 100 kΩ Sorties 0 5Vcc 4 5Vcc avec alimentation 5Vcc résistance de charge recommandée 10 kΩ Sorties 4 20mA avec alimentation 15 36Vcc la résistance de charge maximum admissible est de 200Ω Sorties 4 20mA avec alimentation 15 36Vcc la résistance de charge maximum admissible est de 500kΩ MONTAGE Installer le capteur en ut...

Page 4: ...100 kΩ Uscite 0 5Vdc 4 5 Vdc con alimentazione 5 Vdc si raccomanda una resistenza di carico 10kΩ Uscite 4 20 mA con alimentazione 15 36Vdc la resistenza di carico massima ammissibile è 200Ω Uscite 4 20 mA con alimentazione 15 36Vdc la resistenza di carico massima ammissibile è 500Ω MONTAGGIO Montare il sensore utilizzando viti M5 in acciaio inox amagnetico es AISI 316 o ottone non fornite Utilizza...

Reviews: