4.3.5
Select a location in windy areas
To prevent exposure to wind, install the unit with its suction side facing the wall. The outdoor unit should be installed with consideration
of the direction of strong winds. These can make the unit turn over, so the side of the unit should be set to face the wind, not the front of
the unit.
1
1
2
1. Strong wind
2. Blown air
4.4
Outdoor unit installation
The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the
outdoor unit is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support(wall
or ground).
▪
Fix the outdoor unit with anchor bolts.
N
The anchor bolt must be 20 mm or higher from the base surface.
Caution
When tightening the anchor bolt, tighten the rubber washer to pre-
vent the outdoor unit bolt connection part from corroding. Make a
drain outlet around the base for outdoor unit drainage.
620
940
328
344
384
1
660
880
310
340
364
1
5kW
9-16kW
1. Anchor bolt hole