DHP-AX – 26
VUBMI102
Sub-menu TEMPERATURE
5.1.4
In the TEMPERATURE menu you are able to view the
various temperatures that the installation has had.
All temperatures are stored 60 minutes (factory set-
ting) back in time so that they can also be displayed
in the form of graphs.
Menu text
Description
Adjusted by:
OUTD
Shows the actual outdoor temperature.
ROOM
If ROOM shows 20°C the heat curve is
unaffected. If ROOM shows higher or
lower, this indicates that the heat curve
has been adjusted up or down to change
the indoor temperature.
By the customer, if
necessary.
SUPPLY LINE
Shows the actual supply temperature.
(The desired value is shown between
brackets.)
Read section ”3 Regulation information”
for more information.
(In operating mode AUX. HEATER the
stop temperature for hot water produc-
tion is shown in brackets, increased by
5°.)
Not adjustable
(The computer calcula-
tes the temperature
required to maintain
the indoor tempera-
ture.)
RETURN LINE
Shows the read return temperature. (The
highest permitted temperature is shown
between brackets.)
Authorized installer.
Adjusted for each instal-
lation.
HOT WATER
Shows the actual hot water temperature. Not adjustable
INTEGRAL
Heat production is controlled by a cal-
culated demand that is automatically
calculated when the installation is in
operation. The calculated value for inte-
gral displays the heating system’s actual
energy balance.
Read section ”3 Regulation information”
for more information.
Not adjustable
REFR 1
Shows the actual temperature of the
refrigerant.
Not adjustable
OUTD
ROOM
SUPPLY LINE
RETURN LINE
HOT WATER
INTEGRAL
REFR 1
0°C
20°C
38(40)°C
34(48)°C
52°C
-660
-7°C
TEMPERATURE