Fig. 1: Positioning heat pump
N
Avoid placing the heat pump near windows or walls to noise sensitive areas.
N
Ensure that there is sufficient distance to neighbouring properties so that they are not exposed to noise. Ap-
plicable local regulations must be followed.
N
The heat pump must not be built in into any cabinet or similar.
N
Keep the heat pump and its immediate area free of snow, ice, leaves etc.
>500 mm
>300 mm
>500 mm
>500 mm
>1000 mm
Fig. 2: Installation space
N
Remember that the heat pump must have a certain amount of space in order to function and for servicing.
Otherwise there is a risk that the air will recirculate from exhaust to intake. Avoid this by following the dimen-
sions given above.