DEVIreg™ 531
Installation Guide
4
1.1
Technical Specifications
Operation voltage
220-240 V~, 50 Hz
Standby power consump-
tion
Max 0.25 W
Relay:
Resistive load
Inductive load
Max 15 A / 3450 W @ 230 V
cos φ= 0.3 max 1 A
Sensing units
NTC 15 kOhm at 25 °C
Sensing values:
0 °C
25 °C
50 °C
42 kOhm
15 kOhm
6 kOhm
Hysteresis
± 0.2 °C
Ambient temperature
-10 to +30°C
Frost protection temper-
ature
5 °C -
Temperature range
( ) 5-35°C with room
sensor
Cable specification max
1 x 4 mm² or 2 x 2,5 mm²
Ball pressure temperature
75 °C
Pollution degree
2 (domestic use)
Type
1C
Storage temperature
-20 to +65°C