ATEX technical specifications

The technical specifications in this chapter are supplemental for ATEX systems only. For comprehensive

technical specifications, including maximum pressure rating, maximum flow, etc. please refer to the

standard D1P Technical Information document.

Danfoss does not claim responsibility for the use of the pump in operating conditions not allowed
according to the information shown in this document and the standard D1P Technical Information
document.

Painting or coating can be an electric insulator if a thickness greater than 200 um is applied. The
thickness of the paining of original DPS paint is less than 200 um.

T-codes and maximum surface temperature

Gaseous environment (G)

Ambient oil temperature

Maximum oil

temperature

Maximum ambient temperature

≤ 20 °C [64 °F]

≤ 40 °C [104 °F]

≤ 60 °C [140 °F]

≤ 20 °C [68 °F]

T5

T5

T5

≤ 40 °C [104 °F]

T5

T5

T4

≤ 60 °C [140 °F]

T5

T4

T4

≤ 80 °C [176 °F]

T4

T4

T3

≤ 115 °C [239 °F]

T3

T3

T3

T-codes maximum surface temperature

Temperature class

Maximum surface temperature

°C

[°F]

T3

200

392

T4

135

275

T5

100

212

To ensure that the surface temperature will not exceed the allowed value according to the used
temperature class, it is recommended to attach a temperature sensor to the pump in the shown area on
one of the side surfaces near the maximum displacement limiter at the bottom side of the pump.

Location to attach temperature sensor

Oil types / Operating fluids

In a hydraulic system the most important task of the oil is to transfer energy. At the same time the oil
must lubricate moving parts in hydraulic components, protect them from corrosion, and transport dirt
particles and heat out of the system. To ensure that hydraulic components operate without problems
and have long operating life it is therefore vital to select the correct oil type with the necessary additives.

User Manual

ATEX certified D1P 130/145/193/260

Technical information

 

©

 Danfoss | August 2021

BC376161003883en-000101 | 7

Summary of Contents for D1P130

Page 1: ...User Manual ATEX certified Axial piston pump variable displacement D1P130 D1P145 193 260 www danfoss com...

Page 2: ...Revision history Table of revisions Date Changed Rev August 2021 First edition 0101 User Manual ATEX certified D1P 130 145 193 260 2 Danfoss August 2021 BC376161003883en 000101...

Page 3: ...ting fluids 7 Viscosity and temperature for D1P pump 8 Ambient temperature 8 Oil temperature 8 Viscosity 8 Filtering 9 Installation operation and maintenance Assembly of D1 pump to the system 10 Opera...

Page 4: ...afety The safety of the product depends upon the strict observation of the indications given in this User Manual in particular it is necessary to Always operate within allowed product working operatin...

Page 5: ...Ex II 3G Ex h IIA T3 Gc AN3 temperature class T3 CE Ex II 3G Ex h IIA T4 Gc AN4 temperature class T4 CE Ex II 3G Ex h IIA T5 Gc AN5 temperature class T5 See Viscosity and temperature for D1P pump on p...

Page 6: ...ly explosive atmospheres With following parameters Equipment group II Zone 2 gas Equipment Category 3G Temperature class T5 T3 Explosion protection group II A The Conformity Assessment Procedure has t...

Page 7: ...40 F T5 T4 T4 80 C 176 F T4 T4 T3 115 C 239 F T3 T3 T3 T codes maximum surface temperature Temperature class Maximum surface temperature C F T3 200 392 T4 135 275 T5 100 212 To ensure that the surface...

Page 8: ...account by the safety margin to the minimum ignition temperature of the dust concerned For up to 5 mm 1 97 in layer thickness the safety margin is 75 C 167 F For further information please see IEC 600...

Page 9: ...t the actual operating temperature Filtering It is necessary to keep the level of oil contamination at an acceptable level to ensure problem free operation The recommended maximum level of contaminati...

Page 10: ...200 C for Group 11G Make sure that all type of accessory installed on the pump are ATEX specified and have been installed in accordance with ATEX requirements There are no creeping metal elements exte...

Page 11: ...shaft with inlet pressure in the rear port Generic illustration shown 3 Select the hydraulic fluid as specified in Oil types Operating fluids 4 Ensure full contact between pump mounting flange and con...

Page 12: ...eanliness level b Replace oil filter or change the hydraulic fluid if the required cleanliness level is not reached Operational checks The product is a component which requires no settings or changes...

Page 13: ...color bad smell acidity increase and because of the generation of sludge inside the tank In case symptoms of this kind are detected the system oil must be immediately changed Water presence The prese...

Page 14: ...ause injury to the technician or bystanders To protect against unintended movement secure the machine or disable disconnect the mechanism while servicing Follow the manufacturers instructions for secu...

Page 15: ...nfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distric...

Reviews: