Pump service overview
This manual includes information on maintenance, troubleshooting, and minor repair of D1P pumps.
Performing minor repairs may require removal from the vehicle/machine. Thoroughly clean the unit
before beginning maintenance or repair activities. Since dirt and contamination are the greatest enemies
of any type of hydraulic equipment, follow cleanliness requirements strictly. This is especially important
when changing the system filter and when removing hoses or plumbing.
A worldwide Global Service Partner Network is available for major repairs. Major repairs require the
removal of the unit’s endcap, which voids the warranty unless done by a Global Service Partner. Danfoss
Global Service Partners are trained by the factory and certified on a regular basis. You can locate your
nearest Global Service Partner using the distributor locator at
For detailed technical information, refer to the
.
General instructions
Remove the unit
If necessary, remove the unit from the vehicle/machine. Chock the wheels on the vehicle or lock the
mechanism to inhibit movement. Be aware that hydraulic fluid may be under high pressure and/or hot.
Inspect the outside of the pump and fittings for damage. Cap hoses after removal to prevent
contamination.
Keep it clean
Cleanliness is a primary means of assuring satisfactory pump life on either new or repaired units.
Clean the outside of the pump thoroughly before disassembly. Take care to avoid contamination of the
system ports. Cleaning parts by using a clean solvent wash and air drying is usually adequate.
As with any precision equipment, you must keep all parts free of foreign material and chemicals. Protect
all exposed sealing surfaces and open cavities from damage and foreign material. If left unattended,
cover the pump with a protective layer of plastic.
Replace all O-rings and gaskets
Danfoss recommends that you replace all O-rings, seals and gaskets. Lightly lubricate all O-rings with
clean petroleum jelly prior to assembly.
Secure the unit
If removed from machine, place the unit in a stable position with the shaft pointing downward. It
will be necessary to secure the pump while removing and torquing fasteners and components.
Safety precautions
Unintended Machine Movement
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders.
Secure the machine or disable/disconnect the mechanism while servicing to protect against unintended
movement.
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Introduction
©
Danfoss | July 2019
L1527453 | AX00000292en-CN0201 | 5