S characteristic
0
0
Q max
Flo
w
Pressure
P setting
For additional system protection, install a relief valve in the pump outlet line.
NPSN Priority
The Pressure Compensated Control (P) has priority over the Load Sensing Control (S).
Response/Recovery
Load Sensing (LS) Response/Recovery Times @80°C, 1500rpm, LS Setting at 25 bar
Frame Size
Response (msec)
Recovery (msec)
130cc
260
360
145cc
260
360
193cc
1
233
264
260cc
309
327
1
Tested with a LS setting of 20bar
Values may vary depending on application conditions. For more information, please contact Danfoss
Power Solutions
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Operation
12 |
©
Danfoss | July 2019
L1527453 | AX00000292en-CN0201