During calibration, the zero point and the crimping tool inclination are
set. This is required i.e. if the slide bearing plates have been
changed.
The "Calibration" screen is found in the machine settings and is
password protected.
The process is shown in this screen and the next screen:
Select the UNIFLEX calibration mandrel with the in-
dicated number.
Insert crimping dies with the indicated size.
Position the calibration mandrel thin end in the
crimping tool and press the
button.
The machine reaches the calibration pressure.
Position the calibration mandrel thick end in the
crimping tool and press the
button.
The machine reaches the calibration pressure.
Display: calibrated zero point.