Danfoss Heating Solutions 

VICUL202 

3

Installation Guide 

BasicPlus

2

 WT-T Room Thermostat

GB

3. Notes

1.  Correct wiring is essential; using instrument to con-

firm L and N before wiring is recommended.

2.  Don’t remove too much of the insulation cover from 

the wire to avoid short circuit caused by the naked 

wire touching the metal 86 size mounting wall box.

3.  Don’t let the screw press or touch the wire when 

using screws to fix room thermostat in wall box. A 

short-circuit risk exists if the wire insulation cover is 

damaged by the screw, and if the naked wire con-

nects with the screw.

4.  If walls must be painted, mount the room thermo-

stat after painting, to avoid dust or paint material 

penetrating the room thermostat and thus damag-

ing the PCB.

5.  The max. load of relay is 3 A (resistive) or 1 A (induc-

tive, such as pump or motor). The relay will be dam-

aged if the load exceeds the limit.

6.  Don’t cover the thermostat, for instance by hanging 

towels directly in front of it.

7.  The room thermostat should be connected to the 

corresponding loop actuator in individual room 

temperature control.