7
180R9265 / IOM APP 16-22 Appendices - v02 / 01.2013
t
t
5,00
8,00
11,00
14,00
17,00
20,00
23,00
700
800
900
1000
1100
1200
m
3/
h
rpm
1200 rpm version
5,00
8,00
11,00
14,00
17,00
20,00
23,00
700
800
900
1000
1100
1200
1300
1400
1500
m3
/h
rpm
1500 rpm version
Data sheet
APP 16-22
6.
Flushing valve
0
0,5
1
1,5
2
2,5
3
0
50
100
150
200
250
300
350
400
Pres
su
re
dro
p
[b
ar]
Flow [l/min]
Flushing Valve characteristic
7.
Power requirements
Pump
model
Flow
Pressure
rpm
Calc.
factor
60 bar
70 bar
80 bar
l/min
m
3
/h
gpm
870 psi
1015 psi
1160 psi
APP 16
1200
267
16.0
70.5
32 kW
38 kW
43 kW
1180
496
APP 16
1500
263
15.8
69.5
31 kW
36 kW
41 kW
1480
511
APP 17
1200
287
17.2
75.8
35 kW
40 kW
46 kW
1180
498
APP 17
1500
281
16.9
74.2
33 kW
38 kW
44 kW
1480
513
APP 19
1200
314
18.8
82.9
38 kW
44 kW
50 kW
1180
499
APP 19
1500
313
18.8
82.7
37 kW
43 kW
49 kW
1480
509
APP 22
1200
358
21.5
94.6
43 kW
50 kW
57 kW
1180
501
APP 22
1500
362
21.7
95.6
43 kW
50 kW
57 kW
1480
507
The power requirements can be determined using one of the following guiding equations:
l/min
×
bar
16.7
×
m
3
/h
×
bar
0.26
×
gpm
×
psi
Required power =
[kW] or
[kW] or
[kW]
Calc. factor
Calc. factor
Calc. factor
1 hp
= 0.75 kW
1 kW
= 1.34 hp
1 gpm
= 3.79 l/min
1 l/min = 0.26 gpm
1 m
3
/h
= 4.40 gpm
1 gpm
= 0.23 m
3
/h