Page 1: ...FX STP WIFI Calcium Anti pump User Manual 2022 03 11 Kamoer Fluid Tech Shanghai Co Ltd www kamoer net ...

Page 2: ...X STP WIFI Quick Start Guide to understand the usage process For more product information please read the FX STP WIFI User Manual Quick search keywords PDF electronic documents can use the lookup feature to search for keywords For example in Adobe Reader Windows users use the shortcut ctrl F and Mac users can search for keywords using Command F Click on the catalog to jump Users can learn about th...

Page 3: ...nterference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the device and receiver Connect the device into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for com...

Page 4: ... Kamoer Remote find the corresponding icon of the app download The Kamoer Remote App supports Android 4 4 and above and iOS 9 1 and above Get the Tutorial After installing the App and opening click the button in the upper left corner of my module on the device list page to enter my module click tutorial in my module enter the tutorial module click into the corresponding device model including user...

Page 5: ...Kamoer Fluid Tech Shanghai Co Ltd FX STP WIFI User Manual 5 1 2 3 4 ...

Page 6: ...Product Overview 9 Brief Introduction 9 Feature Highlights 9 Applications 10 Out of the Box Preparation 10 Part Name and Line Connection 10 Product Installation 13 Operate the device with a knob 15 Screen Status Description 15 Pump Operation Control 16 Pump Menu Description 16 Calibration 17 APP Use 20 Connect Titration Pumps to the Cloud 20 Binding Titration Pump 24 ...

Page 7: ...i Co Ltd FX STP WIFI User Manual 7 Overview of Calcium Anti pump Control Interface 25 Setting Up the Interface 27 Flow Calibration 28 Firmware Upgrades 30 Attached 32 Technical Parameters 32 After sales Warranty Information 32 ...

Page 8: ...Kamoer Fluid Tech Shanghai Co Ltd FX STP WIFI User Manual 8 Product Overview This chapter mainly introduces the characteristics of FX STP WIFI calcium anti pump application and out of box instructions ...

Page 9: ...n size Simple structure easy maintenance quick replacement of pump tube Pharmed BPT imported pump tube with standard long life heat acid and alkali resistance ozone and UV rays anti aging and oxidation With display intuitive view of status parameters With potential knob situ at the temperature to facilitate the adjustment of pump parameters Support for flow calibration Includes real time clock run...

Page 10: ...aged during transport After opening the box refer to the packing list in the appendix to make sure that all parts are not missing and check for visible breakage Contact the manufacturer immediately if any defects are found during the out of box process Part Name and Line Connection 1 2 3 4 5 6 1 Display 2 Adjustment knob 3 Adjusting Screws 4 Inlet 5 Outlet 6 DC24V Power Connector ...

Page 11: ...hai Co Ltd FX STP WIFI User Manual 11 Speed Adjustment Button Display screen Connect Sea tank 3 2 6 4 Tube Connect Calcium Anti pump 6 4 9 6 Tube 1 8 to 1 4 connector 3 2 6 4 Tube 24V Power supply Back Line Connection Diagram ...

Page 12: ...Kamoer Fluid Tech Shanghai Co Ltd FX STP WIFI User Manual 12 Product Installation This chapter focuses on how to install the FX STP WIFI calcium anti pump as well as the precautions during installation ...

Page 13: ...honing and return the titration pump should be placed in a reasonable position to ensure that the height difference between the inlet and the outlet is within 0 5 meters The connection tube of the inlet should be as short as possible and the drain connection tube should be suspended above the cylinder Please carefully check the direction of connection between the inlet and outlet is correct never ...

Page 14: ...Kamoer Fluid Tech Shanghai Co Ltd FX STP WIFI User Manual 14 Operate the device with a knob This chapter focuses on how to control FX STP WIFI calcium anti pump using the knob on the device ...

Page 15: ... normal at which point the device can be operated via an App connection NET S Indicates that the device is in the distribution network state need the user network to complete before the normal networking NET F1 Indicates that the device failed to connect to the router NET F2 Indicates that the device successfully connected to the router but failed to connect to the cloud d Flow Display Shows the f...

Page 16: ...the knob the pump stop Control the speed of the pump in the state of pump operation the rotary button can adjust the flow rate of the pump the speed of the rotary button pump increases the counterclockwise rotary button reduces the flow rate the speed of the rotary button can control the speed of the adjustment flow rate Pump Menu Description Menu WiFi Settings lang Cal Work Mode NET O 60 0ml min ...

Page 17: ...stable through the rotary button to rotate the cursor to the speed press the button into the speed editing state through the rotary button to modify the speed press the knob again exit the speed editing state Calibrate 48 0ml min E 120 0rpm 60s Calibrate 48 0ml min 120 0rpm 60s c Calibration time calibration time fixed to 60 seconds when the cursor on the calibration time press the button the pump...

Page 18: ... to move the cursor to the speed selection item b Press the button to enter the speed editing the speed editor under the spin button edit the speed after editing press the button again to complete the editing c Rotate the button to the calibration time item and press the button to start the calibration d Waiting for the countdown to the calibration to be completed e When the countdown to the calib...

Page 19: ...Kamoer Fluid Tech Shanghai Co Ltd FX STP WIFI User Manual 19 APP Use This chapter focuses on how to use the App to control FX STP WIFI calcium anti pump ...

Page 20: ...the mobile phone app remote operation first of all the device configuration to connect to the network the specific operation steps are as follows 1 2 1 2 Open the app click the button button in the upper right corner of the device to add the device select Add device to enter the add device interface select Kamoer FX STP in the list of supported devices and click Enter ...

Page 21: ...connection requires Wi Fi with a network and make sure that the Wi Fi can be connected to the extranet the device does not support 5G Wi Fi and cannot use 5G Wi Fi hot spots 4 Enter the Wi Fi password pay attention not to lose the wrong password click next into the device network operation ...

Page 22: ... start the distribution network Work Mode NET F1 60 0ml min Menu lang Cal WiFi Settings WiFi Network WiFi Setting b a c d a In the pump stop running state the rotary button enters the menu b Rotate the button to WiFi and press the button to enter the distribution network interface c Rotate the button to the distribution network option and press the button d Enter the distribution network state con...

Page 23: ... list interface at which point red light is long representing the titration pump has been connected to the cloud the user has also completed the binding to the titration pump a Configure the device to connect to Wi Fi only once and once the configuration is successful as long as the app can be connected to the network open the app and find the device in the device list b If the device configuratio...

Page 24: ...via a wireless router where the phone can be connected to the wireless router and the app will be available locally Users can click on the corresponding device in the list of devices scanned by the local available device and bind it as follows 1 2 1 2 Open the app click the button in the upper right corner of the device to add the device select Add device to enter the add device interface select t...

Page 25: ... the success of the binding will pop up the binding success prompt click to start back to the list of devices Overview of Calcium Anti pump Control Interface Open the app and click on the calcium anti pump in the device list to enter the calcium anti pump operator interface ...

Page 26: ...click on the settings c Maximum flow rate The maximum flow rate of this machine d Current speed Change according to the set flow rate e Pump tube use time record the length of use of the pump tube in the setting can be set the life of the pump tube f Start Stop Pump Start Stop button g Settings Click to enter the pump information settings and view the interface ...

Page 27: ...on a b c d e f g h a Firmware version indicates which pump head the name of the pump head is set in the settings module b b Device name device name user can modify as needed c Serial number device serial number d Firmware Update If the device has a new firmware you can click on the update here e Pump tube settings set the life of the pump tube here and view the length of ...

Page 28: ...o improve the accuracy of the added elements Click Flow Rate Calibration in the setup interface to enter the calibration pump head selection interface select the pump head that needs to be calibrated and enter the flow calibration interface Calibration needs to use the barrel the pump factory has been equipped with a 10ML measuring tube taking into account the pump tube titration concentration is ...

Page 29: ...hat the accuracy of the rear calibration will not be affected d Long drip timing set the running time of the pump during calibration Before proceeding to the next step make sure that the pump pipe inlet has been immersed in water the pump pipe outlet is placed in the measuring tube e Start titration click the titration button and the pump will stop after running the duration of the previous set f ...

Page 30: ...firmware update is completed the display status after the firmware update is completed The steps for the upgrade are as follows Enter the App settings interface if found that a new version of the firmware appears click b update button to update the firmware this time do not do other operations do not exit the app or re enter the app wait until the upgrade is complete The upgrade is complete and th...

Page 31: ...Fluid Tech Shanghai Co Ltd FX STP WIFI User Manual 31 fails repeat the upgrade step Note You cannot power down during the upgrade and the app does not take any other action during the upgrade process Attached ...

Page 32: ...nformation 1 Warranty Conditions Warranty free service is limited to the user manual under normal use and maintenance is effective all person for failure or damage is not covered by the warranty Users please take good care of the purchase of machine invoices user manuals so that you can get satisfactory after sales service in a timely manner 2 Warranty Coverage Within one year from the date of pur...

Page 33: ...pply 3 All kinds of insects into the machine and cause the circuit board short caused by the damage of components 4 Loss caused by accident 5 Use of inappropriate spare parts non company spare parts not applicable 6 Non authorized personnel negligence handling modification or repair Please don t dismantle and decorate without permission 7 Failure or damage caused by use outside the applicable sett...