Service guide | Disassembling and Assembling, APP(W) 5.1-10.2
© Danfoss | DCS (im) | 2017.06
180R9238 | DKCFN.PI.078.F3.02 | 521B1196 | 6
11. Mount the seal retainer ring Tighten the
ring with a torque of 60 ± 5 Nm.
Turn each screw 2 rounds at a time to
ensure the flange is mounted as straight as
possible Tighten the screws to a torque of
30 ±3 Nm.
To prevent seizing-up, lubricate
the threads on the 8 screws with grease,
screw them into the pump and tighten by
hand. Use Molykote® D paste from Dow
Corning or Klüber UH1 84-201 from Klüber
lubrication.
10. Screw the 8 screws into the flange and the
housing.
8. Position the guide pin in the housing.
9. Position and carefully press, by hand, the
combined flange and swash plate into the
housing.
IMPORTANT: Ensure not to cut the O-ring.
2. Turn the mounting flange upside down.
1. Unscrew the screw in the mounting flange.
3. Disassembling swash
plate
Guide pin