Liquid Level Sensor, AKS 4100/4100U

Ordering AKS 4100/4100U

Cable

 version - AKS 4100/4100U

Description

Code number

With HMI

Code number

Without HMI*

AKS 4100

 with 5 m (197 in.) Ø2 mm (Ø0.08 in.) stainless 

cable and counterweight

 084H4501

 084H4500

AKS 4100U

 with 5 m (197 in.) Ø2 mm (Ø0.08 in.) stainless 

cable and counterweight

 084H4521

 084H4520

Description

Probe length

Code number

With HMI

Code number

Without HMI*

mm

in.

AKS 4100

 - Coaxial  

500

084H4510

084H4503  

AKS 4100

 - Coaxial   

800

084H4511

084H4504  

AKS 4100 

- Coaxial 

1000

084H4512

084H4505  

AKS 4100 

- Coaxial 

1200

084H4513

084H4506  

AKS 4100 

- Coaxial 

1500

084H4514

084H4507  

AKS 4100 

- Coaxial 

1700

084H4515

084H4508  

AKS 4100 

- Coaxial 

2200

084H4516

084H4509  

AKS 4100U 

- Coaxial 

19.2

084H4530

084H4524  

AKS 4100U 

- Coaxial 

30

084H4531

084H4525  

AKS 4100U 

- Coaxial 

45

084H4532

084H4526  

AKS 4100U 

- Coaxial 

55

084H4533

084H4527  

AKS 4100U 

- Coaxial 

65

084H4534

084H4528  

AKS 4100U 

- Coaxial 

85

084H4535

084H4529  

Coaxial

 version - AKS 4100/4100U (available in predefined lengths, with or without HMI)

Accessories

Description

Code number

AKS 4100/4100U

 HMI Service/Display unit with rear cover and mounting bracket

084H4540 

AKS 4100/4100U

 HMI Display

084H4548

Description

Code number

AKS 4100/4100U

 Signal Converter 

without

 HMI, excluding cable gland 

084H4541

Service kits

Description

Content

Code number

Cable and counterweight for

AKS 4100/4100U

 - CABLE version

Cable - 5 m (197 in.) Ø2 mm (Ø0.08 in.)

084H4542

Crimp
Counterweight

End connector incl screws for

AKS 4100/4100U

 - COAXIAL version

End connector (incl. 3 mm (0.12 in) 

set screws)

084H4549

Process connection, counterweight and 

5 m (197 in.) Ø2 mm (Ø0.08 in.) cable for 

AKS 4100

 - CABLE and COAXIAL version

1in. process connection

084H4545

Counterweight

Process connection, counterweight and 

5 m (197 in.) Ø2 mm (Ø0.08 in.) cable for 

AKS 4100U

 - CABLE and COAXIAL version

3/4in. NPT process connection

084H4546

Counterweight

Description

Code number

AKS 4100/4100U

 Coaxial tube. Tube length : 680 mm (26.8 in.)

084H4543

AKS 4100/4100U

 blank top cover for signal converter

084H4544

AKS 4100/4100U

 Aluminium gaskets (10 pcs.) for 1in. process connection

084H4547

AKS 4100 

1. in. welding connection

027F1010 

Other spare parts

*  When ordering

  without HMI  

 

  please observe:

Each AKS 4100/AKS 4100 

must always be programmed 

via the HMI display unit. 

The HMI display unit can be 

ordered separately and there 

are two possibilities:

• 

084H4540

 

AKS 4100/4100U HMI display 

unit with rear cover and 

mounting bracket.  

The mounting bracket is 

very useful when the AKS 

4100/4100U have to be 

programmed.  

The same AKS 4100/4100U 

HMI display unit can be used 

to programme more AKS 

4100/4100U and both Cable 

and Coaxial versions. 

• 

084H4548

 

AKS 4100/4100U HMI display 

unit (usually spare part). 

Summary of Contents for AKS 4100

Page 1: ...cations Dust foam vapour agitated surfaces boiling surfaces changes in density or in the dielectric constant εr for the liquid have no influence on the AKS 4100 4100U performance Oil accumulated in the bottom of a standpipe will not disturb the liquid level signal and it is not necessary to remove AKS 4100 4100U for cleaning after oil has been drained out of the standpipe AKS 4100 4100U Coaxial Ve...

Page 2: ...cal data 5 Measuring range of AKS 4100 4100U CABLE version 6 Measuring range of AKS 4100 4100U COAXIAL version 7 Ordering AKS 4100 4100U 8 Dimensions and weights 9 Technical data 10 Quick setup CABLE version 12 COAXIAL version 13 Forcing mA output 14 Entering refrigerant dielectric gas constant 14 Saturated vapour dielectric constant 15 How to change the language setting Default English 16 Reset t...

Page 3: ...tion prior to mounting signal converter Setting label With the cable version it is possible to adapt the AKS 4100 4100U to any possible length in the range of 800 mm 31 5 in to 5000 mm 196 9 in Danfoss M84H0001_1 Danfoss M84H0021_1 CABLE version COAXIAL version AKS 4100 4100U is available in two different versions Cable version Coaxial version Cable version Both Cable and Coaxial versions are avai...

Page 4: ...e device unable to provide a correct measurement communication memory problem 2 No Reference Pulse 3 Low Voltage or Measurement Old 4 Level Lost Keypad buttons Flashing star indicating unit in operation Enter menu system Enter QUICK SETUP Unit change at distance level readout m cm mm in ft Change between Distance Level Output Output mA AKS 4100 The optional HMI Service Display unit is used for com...

Page 5: ...rature supply voltage limitations 40 C 80 C 40 F 176 F 16 30 V d c 20 C 80 C 4 F 176 F 14 30 V d c Load RL Ω Uext 14 V 20 mA Default Error output set to 3 6 mA RL Ω Uext 14 V 22 mA Error output set to 22 mA Cable gland AKS 4100 PG 13 M20 1 5 cable diameter 6 8 mm 0 24 0 31in AKS 4100U in NPT Refrigerant temperature 60 C 100 C 76 F 212 F Ambient temperature 40 C 80 C 40 F 176 F For HMI 20 C 60 C 4 ...

Page 6: ...ace level Values to be entered into HMI Quick Setup menu and recorded on the setting label Stick the setting label onto the Signal Converter either inside or outside Bottom deadzone values based on the factory setting of dielectric constant Refrigerant Probe length range Bottom dead zone mm in mm in Ammonia HFC HCFC 800 31 5 115 4 2 801 999 31 5 39 120 4 7 1000 1999 39 79 150 5 9 2000 2999 79 118 ...

Page 7: ...one mm in mm in Ammonia 500 19 7 80 3 2 800 31 5 1000 39 4 1200 47 2 1500 59 1 1700 66 9 2200 86 6 Factory setting Refrigerant Probe Length Bottom Dead Zone Bottom Dead Zone mm in mm in HCFC HFC 500 19 7 115 4 5 800 31 5 124 4 9 1000 39 4 130 5 1 1200 47 2 136 5 4 1500 59 1 145 5 7 1700 66 9 151 5 9 2200 86 6 166 6 5 Improved Bottom dead zone values after the adjustment of dielectric constant Refr...

Page 8: ...al Converter without HMI excluding cable gland 084H4541 Service kits Description Content Code number Cable and counterweight for AKS 4100 4100U CABLE version Cable 5 m 197 in Ø2 mm Ø0 08 in 084H4542 Crimp Counterweight End connector incl screws for AKS 4100 4100U COAXIAL version End connector incl 3 mm 0 12 in set screws 084H4549 Process connection counterweight and 5 m 197 in Ø2 mm Ø0 08 in cable...

Page 9: ...and weights CABLE version Probe length Ø104 mm Ø4 1 in 141 3 mm 5 6 in 34 2 mm 1 4 in Ø2 mm Ø0 08 in Ø22 mm Ø0 9 in Ø92 mm Ø3 6 in 33 mm 1 3 in COAXIAL version Ø104 mm Ø4 1 in 141 3 mm 5 6 in 34 2 mm 1 4 in Lunghezza sonda Ø14 mm Ø0 6 in Ø21 mm Ø0 8 in Weight approx 2 0 kg 4 4 lbs Weight approx 3 5 kg 7 7 lbs ...

Page 10: ...ainless steel tubes supporting the available probe length LCD display Max measuring range Coaxial AKS 4100 500 800 1000 1200 1500 1700 and 2200 mm AKS 4100U 19 2 30 45 55 65 85 in Single cable Ø2 mm 0 08 in 800 5000 mm 31 5 197 in Dead zone This depends on the type of probe see pages 7 and 8 Display and User interface Display Integrated LCD display 128 64 pixels in 8 step greyscale with 4 button k...

Page 11: ...Input and output Current output Output signal 4 20 mA or 3 8 20 5 mA acc to NAMUR NE 43 Resolution 3 μA Temperature drift Typically 75 ppm K Error signal High 22 mA Low 3 6 mA acc to NAMUR NE 43 Hold frozen value not available with NAMURNE 43 compliant output Approvals and certification CE This device fufills the statutory requirements of the EMC directives The manufacturer certifies successful te...

Page 12: ...se the value or to increase the value Press to confirm Press to change of SCALE 20 mA Press to change the cursor position Press to decrease the value or to increase the value Press to confirm Wait for QUICK SETUP to complete 8 second timeout AKS 4100 QUICK SETUP COMPLETED IN 8 AKS 4100 1 0 0 QUICK START AKS 4100 1 0 0 STORE NO AKS 4100 DISTANCE 5000 mm Press to confirm Press or to select either ST...

Page 13: ... below are only examples Connect the device to the power supply Press 3 times Press Press or to select between SINGLE or COAXIAL Choose COAXIAL and press to confirm Press NO to confirm AKS 4100 QUICK SETUP YES NO AKS 4100 PROBE TYPE SINGLE CABLE Press to change the PROBE LENGTH Press to change the position of the cursor Press to decrease the value or to increase the value Press to confirm Press to...

Page 14: ...dielectric constant of refrigerant gas completed Entering refrigerant dielectric gas constant all values below are only examples Optional Procedure If the temperature condition in the stand pipe is known a constant dielectric constant of the refrigerant gas can be entered parameter 2 5 3 GAS EPS R in order to obtain lower Top and Bottom Dead Zone values see pages 7 and 8 Default screen Press Press...

Page 15: ... 21 60 70 1 06 22 26 71 79 1 07 27 31 80 88 1 08 32 35 89 95 1 09 36 39 96 102 1 10 40 42 103 108 1 11 43 45 109 113 1 12 46 48 114 118 1 13 R22 Temperature range 50 C 48 C 58 F 118 F Temperature C Temperature F Dielectric constant of refrigerant gas Parameter 2 5 3 GAS EPS R 40 0 18 40 0 1 01 17 4 1 25 1 02 3 5 26 41 1 03 6 13 42 56 1 04 14 20 57 68 1 05 21 25 69 77 1 06 26 30 78 86 1 07 31 34 87...

Page 16: ...reen appears Language setup completed How to change the language setting Default English AKS 4100 QUICK SETUP YES NO Default screen Press once and twice Press AKS 4100 DISTANCE 5000 mm AKS 4100 DISTANCE 5000 mm Enter password Press twice Press Press Select YES by pressing and confirm with Press 3 times to return to default screen Default screen appears Factory reset completed Reset to factory sett...

Reviews: