Servo Control Orifice Reassembly
1. Install the orifice (G020), and torque to 2.7 N•m [23 in•lb]. Then install the orifice backup plug (G030),
and torque to 2.7 N•m [23 in•lb].
2. Install the PC spool (C132), spherical end first, into the PC bore. Install plug (C103). Torque the plug to
12 N•m [8.9 lbf•ft].
3. Using petroleum jelly to retain them, install the four O-rings (C200) in the recesses on the control
housing.
4. Install the control assembly onto the endcap using four screws (C300). Torque the screws to 6.5 N•m
[4.8 lbf•ft]. Torque screws in a criss-cross pattern and re-torque the first screw to ensure proper torque
retention.
Plug and fitting sizes and torques
If any plugs or fittings are removed from the unit during service, install and torque as indicated here. This
drawing is a composite. Your configuration may differ but the appropriate wrench size and torque can be
found here.
Plug locations, sizes, and torques
K045
K040
P109055
Plug
Wrench
Torque
K040
3/8 inch
95 N•m [70 lbf•ft]
K045
3/8 inch
95 N•m [70 lbf•ft]
Service Manual
Series 45 Frame K2 Open Circuit Axial Piston Pumps
Minor repair
©
Danfoss | April 2017
AX00000301en-US0101 | 37