background image

-

-
-

1 Overview

1.1 Description

This installation guide explains how to replace the cooling fan for iC2-Micro Frequency Converters.

1.2 Items Supplied

Use these instructions with the following items.

Table 1: Items Supplied

Code number

Item description

132G0215

Cooling fan, MA02c

132G0216

Cooling fan, MA01a

132G0217

Cooling fan, MA02a

132G0218

Cooling fan, MA03a

132G0219

Cooling fan, MA04a

132G0220

Cooling fan, MA05a

1.3 Safety Information

Only qualified personnel are allowed to replace the cooling fan described in this installation guide.
For important information about safety precautions for installation, refer to the drive's operating guide.

W A R N I N G

DISCHARGE TIME

The drive contains DC-link capacitors, which can remain charged even when the drive is not powered. High voltage can be

present even when the warning indicator lights are off.

Stop the motor, disconnect AC mains and permanent magnet type motors, and remove DC-link supplies, including battery
back-ups, UPS, and DC-link connections to other drives.

Wait for the capacitors to discharge fully and measure it before performing any service or repair work.

The minimum waiting time is 4 minutes for MA02c and MA01a–MA03a drives, and 15 minutes for MA04a–MA05a drives.

AN406328028809en-000301 / 130R1241 | 1