2.
Source SFI: The System Function ID of the ECDIS. This SFI must be unique on the entire
network.
3.
Location: The location of the ECDIS. E.g. Starboard ECDIS, Conning ECDIS. The location
must be unique within the ECDIS-class of equipment.
4.
Transmission group: IEC61162-450 defined binary re-transmittable transmission group to
be used for transmission.
5.
Destination SFI: The system function ID of the VDR (or similar equipment) to receive the
images.
6.
Transmission time offset: Offset by which the image should be transmitted. This is to
offload the network. IEC61996-1 Ed.2 defines the following:
1.
ECDIS node 1 transmit at time offset 8 seconds
2.
ECDIS node 2 transmit at time offset 12 seconds
3.
ECDIS node 3 transmit at time offset 2 seconds
4.
ECDIS node 4 transmit at time offset 6 seconds
7.
Source port: The transmitting port of the ECDIS.
Two types of data are transmitted as different intervals:
3.
Screenshots (images) every 15 seconds
4.
Chart information whenever new chart cells are displayed, or at least every 10 minutes.
7.2.2 NavBox chart update
It is possible to connect a NavBox to the ECDIS.
The shared path of chart database must be configured for this feature to work. Replace the “????”
with the IP of the NavBox. E.g.: \\192.18.1.1\enc
Please refer to
DBS11425 “User manual for Danelec Marine ECDIS software”
for details of how
to use the NavBox from the ECDIS software.
Summary of Contents for DM800
Page 62: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 62 67...
Page 64: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 64 67...
Page 65: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 65 67...
Page 66: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 66 67...