Installation manual for DM800 ECDIS G2
Copyright Danelec Marine A/S
DBS11427-21
Page 40/67
6.5 Vessel Particulars Setup
Configuring operating parameters of the own ship is very important for the correct functioning of
the system. The own ship parameters are configured in the
Main Menu
Settings
Vessel
Vessel particulars
Vessel dimensions and performance characteristics
panel. Here you can
configure the performance characteristics of the vessel and set precise location of various devices
onboard.
6.5.1 Conning station position
The position of all sensors is defined relative to the position of the conning station. Also, the
position of the conning station is the starting point of the vessel’s velocity vectors and past track.
1.
Go to
Main Menu
Settings
Vessel
Vessel particulars
Vessel dimensions and
performance characteristics
2.
Many safety functions of the ECDIS are based on the vessel’s draft and height.
Set the following parameters:
Maximum draft
Current draft
Maximum height
3.
Position of all sensors is defined relative to the position of the common reference point
(CRP). Position of the CRP is also the starting point of the vessel’s velocity vectors and
past track.
Set the following parameters:
distance between the conning station and the bow (A)
distance between the conning station and the stern (B)
distance between the conning station and the port side (C)
distance between the conning station and the starboard side (A)
Summary of Contents for DM800
Page 62: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 62 67...
Page 64: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 64 67...
Page 65: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 65 67...
Page 66: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 66 67...