background image

User manual for DM700 ECDIS hardware 

Copyright Danelec Marine A/S 

 

MAN11804-10 

 

Page 28/30 

 

3.

 

Verify the DM700 ECDIS is turned on (Status LED must be GREEN). If not, briefly press 
the 

“POWER”

 button on the monitor HMI, or briefly press the 

“POWER”

 button on the 

DPU 700-01, next to the Status LED 

4.

 

If the message “No boot media found” appears, verify the M.2 SATA SDD is inserted in the 
M.2 SATA connector under the service cover. If M.2 SATA SDD is inserted, the M.2 
SATA connector or M.2 SATA SDD is defective. Contact a Danelec service partner for 
further assistance. 

5.

 

If the message “Operating system not found” appears, the ECDIS system software is not 
installed properly and must be reinstalled. Contact a Danelec service partner for further 
assistance. 

 

Summary of Contents for DM700 ECDIS

Page 1: ...User Manual for DM700 ECDIS hardware Document Number MAN11804 Version Number 1 0 Date December 2016 P N hard copy 9303969 10 ...

Page 2: ...User manual for DM700 ECDIS hardware Copyright Danelec Marine A S MAN11804 10 Page 2 30 Revision record Version Date Description 1 0 2016 12 02 Initial version of document ...

Page 3: ... 3 MONITOR HMI 11 3 1 Alert buzzer 11 3 2 ECDIS computer shutdown 11 3 2 1 Software standby 11 3 2 2 Hardware standby 12 3 3 ECDIS computer restart 12 4 MONITOR 13 4 1 Control panel on monitor 13 4 1 1 North Invent WAVE monitor 13 4 1 2 Returning backlight to normal 13 4 2 Control of Monitor 13 4 3 Nominal viewing distance 13 5 SELF TEST 14 5 1 Buzzer in monitor HMI 14 5 2 Test of monitor 14 6 DM7...

Page 4: ...1 Stand alone configuration 21 7 3 2 Cluster configuration 21 7 4 Install software update 21 7 5 Software Version 22 7 6 Verification of System Software Version 23 8 HARDWARE ERRORS 24 8 1 List of hardware alerts 24 8 2 Diagnose errors malfunctions 27 9 APPENDIX A COLOR DIFFERENTIATION TEST 29 ...

Page 5: ...elec Marine A S MAN11804 10 Page 5 30 1 Scope and purpose User manual for DM700 ECDIS hardware 1 1 References DBS11425 User Manual for Danelec Marine ECDIS software P N 9303396 1 2 Terms and Abbreviations ECDIS Electronic Chart Display and Information ...

Page 6: ...r DM700 ECDIS 2 1 System overview A DM700 ECDIS consists of the following parts DM700 ECDIS DPU 700 01 Monitor Keyboard USB 4 DVI 2 x IEC 61162 2 3 x IEC 61162 2 For sensors 2 x Ethernet To other ECDIS s VDR or NavBox COM1 USB 2 DC Power HW KEY USB 1 Chart updates NAV stick LAN 1 2 SI 00 04 M 2 SATA SWAP disk ...

Page 7: ...cover on the DM700 ECDIS DPU 2 1 4 Monitor The monitor supplies power to the DM700 main unit and displays the image from the ECDIS computer The monitor is installed on a table top or flush mounted in the console 2 1 5 Monitor HMI The monitor HMI is used to power the DM700 ECDIS ON and OFF It also includes a buzzer which will sound if an alarm or warning condition occurs in the ECDIS The monitor HM...

Page 8: ...tly together if the cluster contains only two systems The DM700 ECDIS s must be connected using an Ethernet switch if the cluster contains more than two systems Cluster containing 2 x DM700 ECDIS Cluster with 3 x DM700 ECDIS Must be an Ethernet switch which is included on the type approval certificate e g 5 Port Managed Gb Ethernet switch type 1303974 LAN 1 LAN 1 Backup Master LAN 1 LAN 1 LAN 1 Ba...

Page 9: ... be possible to have redundant network connections if DM800 ECDIS G2 and DM700 ECDIS are used together Cluster containing 1 x DM700 ECDIS and 1 x DM800 ECDIS G2 Cluster containing 2 x DM700 ECDIS and 1 x DM800 ECDIS G2 Port1 Port2 LAN 1 DM700 ECDIS Backup DM800 ECDIS G2 Master Port 1 Port2 LAN 1 LAN 1 DM700 ECDIS Backup DM700 ECDIS Planning DM800 ECDIS G2 Master ...

Page 10: ... ECDIS hardware Copyright Danelec Marine A S MAN11804 10 Page 10 30 Cluster containing 1 x DM700 ECDIS and 2 x DM800 ECDIS G2 Port 1 Port2 Port 1 Port 2 LAN 1 DM800 ECDIS G2 Backup DM700 ECDIS Planning DM800 ECDIS G2 Master ...

Page 11: ...f the alarm signal may be adjusted in the ECDIS application Go to the shortcut menu and adjust the volume using the buzzer volume controls see DBS11425 User Manual for Danelec Marine ECDIS software for further details 3 2 ECDIS computer shutdown There are 2 ways to set the ECDIS to standby Software standby Hardware standby To start the system again follow the procedure in section 3 3 ECDIS compute...

Page 12: ...e ECDIS software freezes or stops responding to user input Press and hold the POWER button on the monitor HMI for 7 seconds in order to shut down the ECDIS computer 3 3 ECDIS computer restart Press POWER button in the monitor HMI in order to restart the computer This is applicable both after a hard shutdown see section 3 2 ECDIS computer shutdown or if the ECDIS is in standby after the software ha...

Page 13: ...settings are controlled from the ECDIS Software 4 1 2 Returning backlight to normal If the backlight is turned off and or the monitor mode is set to night it can be difficult to see if the monitor is on Press F6 to switch between monitor modes and use F8 to restore each monitor mode to its calibrated settings 4 2 Control of Monitor The color generating capability of the monitor may deteriorate ove...

Page 14: ...generated if an error in one of these devices is detected 5 1 Buzzer in monitor HMI The buzzer in the monitor HMI may be checked by adjusting the buzzer volume up or down The buzzer will briefly sound at the current audio level if the buzzer volume if adjusted up or down 5 2 Test of monitor Check the colors and the contrast for the monitor visually and if in doubt consult section 4 2 Control of Mo...

Page 15: ... The DM700 main unit must be powered from the DC output on the monitor The monitor must be connected to the ship s main power source 110 230AC The AC power must be backed up by the vessel s emergency power automatic switch over The cables must be as short as possible and have a conductor area of 0 75mm2 minimum The power consumption for the Monitor and DM700 main unit is 80W ...

Page 16: ...1804 10 Page 16 30 6 2 Status LED s 6 2 1 Status LED Off The DM700 ECDIS is in standby or without power Red Reverse power protection is active Green normal operation The DM700 ECDIS is powered on and is probably operating normally Blue flash normal operation Disk activity ...

Page 17: ... Menu should only be used by personnel with proper authorization as incorrect use may result in loss of chart licenses The Management Menu is located in the Settings System Management menu To open the menu do the following 1 Open the Main Menu by clicking the menu icon in the bottom left corner 2 In the Main Menu select Settings 3 In the Settings menu select the System sub menu 4 In the System sub...

Page 18: ...User manual for DM700 ECDIS hardware Copyright Danelec Marine A S MAN11804 10 Page 18 30 5 Enter the MASTER password 6 The Management menu will now open ...

Page 19: ...ndependent See section 7 3 USB hardware keys for further details Mouse Trackball configuration You can adjust the speed of the mouse track in the menu This is relevant if you have replaced the keyboard with integrated trackball with a keyboard of a different type Manually set time date Use this menu to set the BIOS time of the system manually Software update This menu is used for updating the soft...

Page 20: ... it must first be made independent After this it will automatically be made a secondary key in the cluster By opening the USB hardware key management panel you can inspect all the hardware keys in the cluster You can only modify the role of the local hardware key Make primary key Use this button to make the local USB hardware key the primary hardware key in the cluster There may only be one primar...

Page 21: ... USB hardware keys is selected as the primary key The remaining ECDIS will adopt USERPERMIT from the primary hardware key It is possible later on to change which hardware key is the primary key This is probably undesirable as it will render the installed charts and permits useless and new chart permits must be installed If the primary USB hardware key is removed or becomes faulty the remaining ECD...

Page 22: ... After completion of the update the following is shown When clicking OK the ECDIS will restart and the the update is completed 7 5 Software Version The ECDIS system version is displayed in the System Information panel Open Main Menu Settings System System Information To verify that the latest available version is installed see the sections below ...

Page 23: ...lease status and compliance status may be found on the website http www danelec marine com In the ECDIS section of the site look for the ECDIS software information and compliance status page The site shows the released software versions and a list of standards the software ECDIS version complies with Verify that the software version for the ECDIS see previous section matches the latest System soft...

Page 24: ...rd device problem detected x device s expected 1 No or more than one keyboard has been detected If x 0 connect a keyboard If already connected the keyboard may be defective If x 1 and only one keyboard is connected it may be an indication of faulty operation 10204 Caution B USB hardware key device problem detected x device s expected 1 No or more than one USB hardware key has been detected If x 0 ...

Page 25: ...spect the cluster and remove the unwanted primary hardware key 10250 Caution B Incorrect monitor type connected The color in the chart representation will be incorrect The monitor connected is not the configured model type Connect the correct monitor 10301 Caution B No connection to ECDIS system 1 The network connection has been lost to ECDIS node 1 ECDIS 1 Possibly a disconnected or defective net...

Page 26: ... check that link is present for both Ethernet ports 1 and 2 10401 Caution B Low disk space Less than x MB left on disk The disk is almost full The operational state of the ECDIS will soon be compromised Remove unused chart databases 10402 Warning B No space left on disk The disk is full The operational state of the ECDIS is now compromised Remove all unused chart databases routes logbooks etc ...

Page 27: ...SB disk file system Supported formats are FAT FAT32 or NTFS 3 Contact a Danelec service partner for further assistance No data is received from any of the remote ECDIS nodes 1 Verify an Ethernet cable is connected to Ethernet port LAN1 2 Verify the remote ECDIS node is turned on 3 Contact a Danelec service partner for further assistance No sound from the buzzer 1 Verify the monitor is connected co...

Page 28: ...o the Status LED 4 If the message No boot media found appears verify the M 2 SATA SDD is inserted in the M 2 SATA connector under the service cover If M 2 SATA SDD is inserted the M 2 SATA connector or M 2 SATA SDD is defective Contact a Danelec service partner for further assistance 5 If the message Operating system not found appears the ECDIS system software is not installed properly and must be...

Page 29: ... be brought up on the screen and the contrast and brightness controls or equivalent controls for an LCD should be adjusted in a specific way To adjust the contrast and brightness do the following 1 Make sure that the Chart1 database is displayed See DBS1425 User Manual for Danelec Marine ECDIS Software Open Main Menu NAV DATA Chart Library and enable Display of Chart1 2 Locate the Chart1 chart dat...

Page 30: ...ast control but preferably do not adjust the controls unless lighting conditions on the bridge change After the black level has been set you can proceed with the color test For the test you need to display the color differentiation diagram in the chart view 12 Repeat steps 1 3 but instead open cell AA5C1WOO The cell contains the color differentiation test diagram is shown 13 The diagram consists o...

Reviews: