8 Service and maintenance
The S-VDR requires an annual performance test carried out by a certified service organization.
Please refer to “Installation Manual for DM100 S-VDR” for further details.
8.1 Verification of the S-VDR functionality following service on any
sensor
It is a requirement of the S-VDR standard that the functionally of the S-VDR is verified followed
service on any sensor (e.g. the GPS) connected to the S-VDR.
The bridge alarm panel will display obvious errors if, for example the signal from a sensor sending
NMEA sentences is missing completely. However, it is required that recorded data is retrieved and
checked to a certain extent. A tool for doing that is stored on the S-VDR and may be downloaded
via a web browser to the PC.
The following steps are necessary:
- Setting the IP address of the PC to match the S-VDR
- Connecting the PC to the S-VDR
- Running the VDR Verifier program
- Examination of the report
DBS10912-10