058
AUDIO
Power short circuit
One or more microphones are using too much power. The cabling
and microphones must be checked.
060
STATUS
UTC timeout
The system is not receiving UTC from the GPS. Check that the
GPS is on. Check the signal from the GPS (use serial monitor in
VDR explorer, WEB status or VGA status display). If no signal is
present check the cable, otherwise check that the configuration is
done correctly.
070
PSU
Communication failed
The communication between the power supply circuit and the main
CPU in the DPU has been interrupted. If the error persists, the DPU
is probably defective.
074
SERIAL module 1
Missing (SI00-07)
The serial data interface module on the SAP board in the DPU
cannot be detected. If the error persists, the DPU is probably
defective.
076
VIDEO module 1
Missing (VD01-02)
VIDEO module 1 cannot be detected. The most probable cause is
that the cable to the RVI from the DPU is disconnected or the RVI
is defective. Additional causes for an AC powered RVI: Power to
the RVI is switched off, the internal Ethernet cable in the RVI is
disconnected or the video interface module is defective.
078
AUDIO module 1
Missing (BMU1-BMU5)
The audio data interface module on the SAP board in the DPU
cannot be detected. If the error persists, the DPU is probably
defective.
080
082
084
086
VIDEO
VD0n no input
There is no input from the radar. Check the radar and the cable.
Enter the video calibration menu for that channel and examine the
image. Unused video channels must be configured inactive (the
Active parameter must be unchecked).
088
090
092
094
VIDEO
VD0n image too big
The radar image exceeds the allocated space in the capsule and the
system is therefore unable to record for 12 hours. Check the radar
image for noise. Check the calibration of the video channel. Reduce
the number “color mask bits” if needed.
089
091
093
095
VIDEO
VD0n wrong size
The radar image is not the same size as defined in the
configuration. Check the size of the image from the radar. If
correct, check calibration and settings for the video channel.
096
Not configured
Configure VDR
The VDR has started on the default configuration. Configure the
system correctly. The VDR is unable to operate correctly on the
default configuration since at least the GPS antenna position and
vessel ID must be entered.
117
PSU battery
Battery switch “OFF”
The battery switch on the front of the DPU is in the “OFF”
position.
118
PSU battery
Not present
The power supply is unable to detect the battery pack. Check that
the battery pack is connected to the DPU. If the error persists for
more than five minutes, the batteries are probably defective.
120
PSU battery
Could not be charged
The charger was unable to fully charge the battery within a pre-
defined time. Switch the battery switch on the DPU “OFF” briefly
and then “ON”. If the error returns (this may take 18 hours), the
battery pack is defective and must be replaced.
124
PSU
Low output voltage
The output voltage from the battery pack has dropped below 16V.
This message will appear shortly before the battery is discharged
DBS10912-10