Operator's Manual for the DM100 S-VDR
Copyright Danelec Marine A/S
write errors
detected by the fixed capsule over a period of time. The most likely
cause is serious communication problems or a defective fixed
capsule.
706
CAPSULE, too many
read errors
Too many read-errors (reading back data from the fixed capsule)
have been detected by the DAU over a period of time. The VDR
was unable to write and verify data despite several attempts. The
most likely cause is serious communication problems or a defective
fixed capsule.
707
CAPSULE, too many
read errors
Too many read-errors (reading back data from the fixed capsule)
have been detected by the fixed capsule over a period of time. The
VDR was unable to write data despite several attempts. The most
likely cause is serious communication problems or a defective
fixed capsule.
708
CAPSULE
Verification failed
The VDR found too many data errors within a given interval when
verifying the data written to the fixed capsule. The fixed capsule is
probably defective.
709
CAPSULE
Record too big
The amount of data collected for a 15-second period exceeds the
maximum allowed size for the fixed capsule. This is typically
caused by receipt of too much image data. Use the “Analysis of
recorded data” utility on the BCP or in the configurator tool to
determine the cause. If the problem relates to image data, carry out
an OPT and check the recorded images.
710
CAPSULE
Record-data too big
The amount of data received by the VDR exceeds the capacity of
the fixed capsule. This is typically caused by receipt of too much
image data. Use the “Analysis of recorded data” utility on the BCP
or in the configurator tool to determine the cause. If the problem
relates to image data, carry out an OPT and check the recorded
images.
711
CAPSULE
Wrong Attachment
The capsule is connected to the wrong port on the DPU. Connect
the capsule to the port labelled CAPSULE
712
FLOAT-FREE
Wrong Attachment
The float-free is connected to the wrong port on the DPU. Connect
the float-free to the port labelled FLOAT FREE.
901-
933
SYSTEM FAILURE
ERROR 901-933
The software is not working properly. Restart the VDR and report
this error if it is repeated.
970
SELF-TEST
Memory test failed
The amount of RAM is insufficient to start the VDR. Restart the
system. If the error persists, call for assistance.
972
SELF-TEST
VGA failed to init.
Required Video (VGA) circuitry could not be initialized. Restart
the system. If the error persists, call for assistance
980
BAU and DPU not
compatible
The software in BAU is incompatible with the software in the
DPU.
981
No communication
to DPU
The BAU has never been able to communicate with the DPU. The
most probable cause is a defective cable or that the VDR did not
boot correctly.
982
No communication
to DPU
Initial communication took place, but the communication has failed
later. The most probable cause is that the VDR encountered a fatal
error and completely stopped. Restart the system. If the error
persists, call for assistance.
---
Time, VDR
No errors detected
DBS10912-10
Page 22/36