SYSTEM JUNCTION BOX DIAGNOSTIC LIGHTS
Supply Fault:
There are two conditions that cause this diagnostic light to come on:
1.
When this light remains on (but not flashing) it indicates the
machine was turned off by pushing on the Red emergency button on
the control panel. The machine will not function while the light is on.
To reset, pull out the button, turn the key switch off, then on again.
This condition does not require service. (The key switch is the
correct way to turn off the machine when it is stored or set aside for
periods of time.)
2. When this light is flashing, it indicates that there is a problem in
either the beacon post or the control panel. In a fault condition the
“supply fault” light starts flashing as soon as the machine is turned
on with the key switch. The machine will not function while the light
is flashing. The control panel lights may remain lighted for 3-
seconds then shut down but the fault light will remain flashing as
long as the fault condition exists.
To determine if the problem is in the beacon post, turn off the
machine with the key switch, unplug the cable leading to the beacon
post then turn the key switch on again. If the problem is in the
beacon post the machine will operate normally but only in the
“manual” mode. If the problem is somewhere in the control panel
circuitry, the fault light will continue to flash and the panel lights will
go off in about 3 seconds.
Remote Brake:
LED lights to indicate presence of “Brake” command from receiver.
It has no effect in manual mode.
Remote Slow:
LED lights to indicate presence of “Slow” drive command from
receiver. Must light in conjunction with “Drive” Command LED in
“Remote” mode in order to operate machine. It has no effect in
manual mode.
Remote Fast:
LED lights to indicate presence of “Fast” drive command from
receiver. Must light in conjunction with “Drive” command LED in
“Remote” mode in order to operate machine. It has no effect in
manual mode.
Drive Command:
LED lights to indicate drive signal is being sent to motor control.
Low Battery:
LED lights when battery voltage is too low to operate machine
properly (below approximately 27 volts).
Hour Meter:
Hourglass symbol blinks every ten seconds when drive command is
present to indicate that meter is timing machine operation.