5.1 Overview
Rear panel connectors
Front panel connectors, controls and indicators
[1]
powerCON TRUE 1 TOP
®
mains connector socket.
Refer to
Chapter 5.2 "Mains connection" on page 13.
[2]
Ethernet switch with 8 x RJ45 ports.
Refer to
Chapter 5.4 "Rear panel" on page 15.
[3]
etherCON
®
switch ports ETH 9 - ETH 11.
Refer to
Chapter 5.3.1 "ETH 9 - ETH 11" on page 13.
[4]
Mode button.
Refer to
Chapter 5.3.2 "Mode selection" on page 14.
[5]
Multi-colored LED indicators.
Refer to
Chapter 5.3.3 "LED indicators" on page 14.
5.2 Mains connection
WARNING!
Potential risk of electric shock.
The device is a protective class 1 unit. A missing earth (ground)
contact may cause dangerous voltages in the housing and controls
and may lead to electric shock.
▪ Connect the unit to mains power supplies with protective earth
only.
▪ If there is any sign of obvious damage to the power cord
and/or mains connector, do not use the power cord and
replace it before further use.
▪ Please ensure the mains connector is accessible at any time to
disconnect the unit in case of malfunction or danger.
Before connecting the device to mains voltage, check that the
mains voltage and frequency correspond to the specifications on
the rating label above the mains connector socket on the rear
panel of the unit.
A mains connector socket
[1] is fitted on the rear panel and an
appropriate power cord
[1.1] is supplied.
5.3 Front panel
5.3.1 ETH 9 - ETH 11
The DN1 device provides an 11-port Ethernet switch for different
network topologies, redundancy (max. two devices) and advanced
functionality with AVB. Three connectors are provided on the front
panel.
Power over Ethernet
The « ETH 10/PoE» and «ETH 11/PoE» Ethernet connectors also
provide Power over Ethernet based on IEEE standard 802.3af.
Each port delivers a maximum of 15.4 W, both ports deliver a
maximum total of 25 W. If the maximum power is exceeded, PoE
supply will be shut off.
Note: Either of the « ETH 10/PoE» or «ETH 11/PoE» connector is also intended to
feed an inclinometer such as the d&b ArraySight sender unit, which is integrated in
the flying frame for vertical aiming of the entire array.
5 DN1 Ethernet switch
d&b Z5600.002 Manual 1.2 en
13
Summary of Contents for Z5600.002 D40
Page 1: ...D Z5600 002 Manual 1 2 en ...
Page 17: ...Internal 4 CHANNEL OUTPUT wiring d b Z5600 002 Manual 1 2 en 17 ...
Page 18: ...Internal digital audio INPUT and LINK wiring d b Z5600 002 Manual 1 2 en 18 ...
Page 19: ...Internal analog audio INPUT and LINK wiring d b Z5600 002 Manual 1 2 en 19 ...
Page 20: ...Internal Ethernet network wiring d b Z5600 002 Manual 1 2 en 20 ...
Page 21: ......
Page 22: ...D2760 EN 01 06 2022 d b audiotechnik GmbH Co KG www dbaudio com ...