5.3.2  Mode selection

The DN1 device features a «MODE» button on the front panel.
This button is used for three different purposes:

Configuration mode

Toggle between primary and secondary configurations.

Reset mode

Reset the device to remote settings default.

Wink mode (device indentification)

Visual identification of your device.

Configuration mode
If the DN1 device is operated within an AVB network, you must

configure all switches for use in a primary or secondary network.

The DN1 recognizes a primary or secondary connection of the

connected AVB device and indicates an error if a primary port has

been connected to a secondary switch and vice versa.
To enter the Configuration mode, proceed as follows:
1. Select and hold the «MODE» button for two seconds.

Either the «PRI» or the «SEC» LED starts to flash in periods

of one second with an uptime of 50%.

2. Select the «MODE» button to toggle between primary and

secondary configurations.

After five seconds of inactivity, the «PRI» and «SEC» LEDs

leave the Configuration mode and switch back to normal

display mode.

Note: Without an DHCP server in LinkLocal IP mode:
▪ IP adress range in primary mode: 

169.254.xxx

▪ IP adress range in secondary mode: 

172.31.xxx

Reset mode
The remote reset function resets all settings related to remote

communication to factory defaults. To reset the DN1 device to

defaults, proceed as follows:
1. Select and hold the «MODE» button for five seconds.

All AVB port status LEDs turn red for two seconds.

All other LEDs are off.

2. Release the «MODE» button.
3. Within two seconds, select the «MODE» button once again.

All AVB port status LEDs turn red for two seconds.

All other LEDs are off.
Alle remote settings are set to default.

 

Wink mode (device identification)
To activate the Wink mode, proceed as follows:
1. Select the «MODE» button once.

All AVB port status LEDs flash in the color of the current

Configuration mode (  = Primary /   = Secondary).

2. After three seconds, the Wink mode stops automatically.

5.3.3  LED indicators

All device states and operating modes are indicated by dedicated

multi-colored LEDs.

Note: In case of an device error, connect the device to R1 via

OCA to obtain further information.

 

d&b Z5600.002 Manual 1.2 en

14

Summary of Contents for Z5600.002 D40

Page 1: ...D Z5600 002 Manual 1 2 en ...

Page 2: ...larly check the d b website for the latest version of this document When reselling this product hand over this document to the new owner If you supply d b products please draw the attention of your customers to this document Enclose the relevant documents with the systems If you require additional documents for this purpose you can order them from d b d b audiotechnik GmbH Co KG Eugen Adolff Str 1...

Page 3: ...electric shock Do not expose the rack assembly to rain or moisture Keep water or other liquids away Do not place liquid filled containers for example beverages on top of the rack assembly Do not operate the rack assembly while it is wet or standing in liquid 6 Do not use the rack assembly if its mains power cord is damaged or frayed Protect the power cord from being walked upon or pinched particul...

Page 4: ... 2 4 AMP 1 AMP 2 AMP 3 4 CH OUTPUTS 9 3 3 Front panel 10 3 3 1 MAINS 10 3 3 2 AUXILIARY MAINS OUTPUTS 16A 10 3 3 3 AMPLIFIER MAINS OUTPUTS 10 3 3 4 4 CH OUTPUTS NL8 11 3 3 5 12 CH OUTPUT 11 4 Z5604 I O Panel 12 4 1 Intended use 12 4 2 Overview 12 4 2 1 INPUT 12 4 2 2 INPUT LINK 12 4 2 3 Remote network option 12 5 DN1 Ethernet switch 13 5 1 Overview 13 5 2 Mains connection 13 5 3 Front panel 13 5 3...

Page 5: ... audio signals 1 2 Scope of supply Before starting up please verify the shipment for completeness and proper condition of the items If there is any sign of obvious damage do not operate the rack assembly and contact your local dealer from whom you received it Note Depending on the ordered rack assembly variant the rack assembly comprises the following components Pos Qty d b Code Description 1 1 Z5...

Page 6: ...Dimensions and weight Height x width x depth 710 x 600 x 715 mm 28 x 23 6 x 28 2 Total weight 1x DN1 included 110 kg 242 lb d b Z5600 002 Manual 1 2 en 6 ...

Page 7: ...fficient space of 0 5 m 1 6 ft at the front and rear of the touring rack to ensure adequate cooling airflow CAUTION Risk of personal injury and or damage to material due to possible tipping over To avoid possible tipping over do not move stacked touring racks D40 Touring rack assemblies as well as D40 and D20 Touring racks can be stacked or positioned side by side When combining D40 Touring rack a...

Page 8: ...and controls and may lead to electric shock Connect the unit to mains power supplies with protective earth only If there is any sign of obvious damage to the power cord and or CEE mains connector do not use the unit and replace it before further use Do not connect or disconnect the CEE mains connector under load or live Please ensure the mains connector is accessible at any time to disconnect the ...

Page 9: ...wer supply line 3 2 3 AMP 1 AMP 2 AMP 3 MAINS SUPPLY Three fixed single phase mains power lines L1 L2 L3 with dedicated lengths each fitted with a powerCON TRUE 1 TOP mains connector are provided for the internal mains power supply of the amplifiers 3 2 4 AMP 1 AMP 2 AMP 3 4 CH OUTPUTS Three fixed multicore cables with dedicated lengths each fitted with an NL8 connector are provided for the intern...

Page 10: ... on the rear panel One of these sockets is used to apply mains supply for the DN1 device The remaining sockets are intended for the connection of low current devices such as notebooks or additional Ethernet switches The sockets are equipped with dedicated circuit breakers 16 A C Frame type 3 3 3 AMPLIFIER MAINS OUTPUTS Each single phase mains power line is equipped with a dedicated circuit breaker...

Page 11: ...e graphic opposite 3 3 5 12 CH OUTPUT One 12 CH OUTPUT multipin connector LKA25 is provided to allow efficient system wiring using the d b MC24 multicore system Z5328 xxx MC24 LKA25 F M Multicore Z5325 000 Break out adapterLKA25M to 6 x NLT4M Z5327 000 Break out adapter LKA25M to 12 x NLT4M and Z5326 000 Break in adapter 3 x NLT8F to LKA25F The d b MC24 Multicore System combines a 12 amplification...

Page 12: ...s to be fed to the amplifier 4 2 2 INPUT LINK The INPUT LINK section represents the link output connectors of the last third sixt amplifier and allows the linking of further system racks 4 2 3 Remote network option You can daisy chaining the rack assemblies within a remote network using the enclosed rack link cable Z5333 001 For remote purposes via Ethernet OCA it is strongly recommended to use th...

Page 13: ... accessible at any time to disconnect the unit in case of malfunction or danger Before connecting the device to mains voltage check that the mains voltage and frequency correspond to the specifications on the rating label above the mains connector socket on the rear panel of the unit A mains connector socket 1 is fitted on the rear panel and an appropriate power cord 1 1 is supplied 5 3 Front pane...

Page 14: ...eave the Configuration mode and switch back to normal display mode Note Without an DHCP server in LinkLocal IP mode IP adress range in primary mode 169 254 xxx IP adress range in secondary mode 172 31 xxx Reset mode The remote reset function resets all settings related to remote communication to factory defaults To reset the DN1 device to defaults proceed as follows 1 Select and hold the MODE butt...

Page 15: ...vity max 1 Gbit Network activity max 100 Mbit Primary AVB network detected Device in PRI network mode Secondary AVB network detected Device in SEC network mode Active PoE supply LED off Normal operation No active connection No AVB network information No PoE enabled device connected LED flashing Traffic PoE Error 5 4 Rear panel ETH 1 ETH 8 The DN1 device provides a RJ45 8 port panel at the rear of ...

Page 16: ...Mains power connection and internal mains supply distribution 6 Rack wiring diagrams d b Z5600 002 Manual 1 2 en 16 ...

Page 17: ...Internal 4 CHANNEL OUTPUT wiring d b Z5600 002 Manual 1 2 en 17 ...

Page 18: ...Internal digital audio INPUT and LINK wiring d b Z5600 002 Manual 1 2 en 18 ...

Page 19: ...Internal analog audio INPUT and LINK wiring d b Z5600 002 Manual 1 2 en 19 ...

Page 20: ...Internal Ethernet network wiring d b Z5600 002 Manual 1 2 en 20 ...

Page 21: ......

Page 22: ...D2760 EN 01 06 2022 d b audiotechnik GmbH Co KG www dbaudio com ...

Reviews: