background image

 

Cardioid dispersion
Cardioid dispersion avoids unwanted energy behind the system

and greatly reduces the excitation of the reverberant field at low

frequencies providing the greatest accuracy of low frequency

reproduction. The subwoofers can be used as stand-alone solutions

or in stacked combinations with a minimum distance of 60 cm (2 ft)

between adjacent cabinets or between the subwoofers and a side

wall. When positioned in front of walls, the minimum distance to

rear walls is maintained by the wheels mounted at the rear of the

cabinet.

2.2  Connections
The cabinets are fitted with a single NLT4 F connector using the pin

assignment 1+/1– for the front drivers and pins 2+/2– for the

rear driver.

Phoenix option

NOTICE!
Risk of damage to the system components!

Different pin assignment on the loudspeaker and amplifier.

Þ

 Please refer to the corresponding amplifier manual.

Cabinets with Phoenix option are fitted with a 4-pole Phoenix

connector socket (Type: DFK PC 4/4 GF) using the following pin

assignment:
▪ Pins 1+/2– feeding the forward LF drivers.

▪ Pins 3+/4– feeding the rear LF driver.
Phoenix specifications and recommendations
The cabinet comes with a Phoenix plug (Type: SPC 5/4 Push-in

spring connector) which is already connected to the corresponding

Phoenix socket of the cabinet.
The plug allows for direct wire connection without any tools

depending on the cross section and conductor structure.
Technical specifications

Conductor cross section
Flexible, ferrule without plastic sleeve

up to 6 mm

2

 (AWG 9)

Flexible, ferrule with plastic sleeve

up to 4 mm

2

 (AWG 11)

Ferrule length (min/max)

10/15 mm

Release tool

Flat-tip screwdriver 0.6 x 3.5 x 100 mm

Recommended connecting cable

d&b K3116.100 MC2 SWR

2 x 2.5 mm

2

 (AWG 13)

Ferrule without plastic sleeve (enclosed with the cabinet)

d&b LoadMatch
With the d&b four channel amplifier platform, the LoadMatch

function enables the amplifier to electrically compensate for the

properties of the loudspeaker cable used without the need for an

additional sense wire. For applicable loudspeakers, LoadMatch is

therefore independent of the connector type used.

Cardioid dispersion pattern

Connector wiring
NLT4 F
Phoenix option

 

d&b KSLi-SUB/KSLi-GSUB Manual 1.1 en

- perliminary -

7

Summary of Contents for KSLi-GSUB

Page 1: ... perliminary SL KSLi SUB KSLi GSUB Manual 1 1 en ...

Page 2: ...KG all rights reserved Keep this document with the product or in a safe place so that it is available for future reference When reselling this product hand over this document to the new owner d b audiotechnik GmbH Co KG Eugen Adolff Str 134 D 71522 Backnang Germany T 49 7191 9669 0 F 49 7191 95 00 00 docadmin dbaudio com www dbaudio com ...

Page 3: ...SLi GSUB loudspeaker 6 2 1 Intended use 6 2 2 Connections 7 2 3 Operation 8 2 3 1 Controller settings 8 2 4 Technical specifications 8 3 Manufacturer s declarations 10 3 1 EU conformity of loudspeakers CE symbol 10 3 1 1 WEEE Declaration Disposal 10 Contents d b KSLi SUB KSLi GSUB Manual 1 1 en perliminary 3 ...

Page 4: ...iled in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories for visible signs o...

Page 5: ... addition ArrayCalc will provide you with typical array configurations within the permitted load limits and will help you get familiar with the mechanical load conditions and limitations d b TI 385 Further information on line array design can be found in TI 385 d b Line array design ArrayCalc The TI is supplied with the software or can be downloaded from the d b website at www dbaudio com d b Semi...

Page 6: ...quencies providing highest accuracy in low frequency reproduction The frequency response extends from 36 Hz to 105 Hz 33 Hz to 75 Hz INFRA mode The cabinet enclosures are constructed from marine plywood and have an impact and weather protected PCP Polyurea Cabinet Protection finish The front and rear of the cabinets are protected by rigid metal grills Each side panel incorporates two slots to acce...

Page 7: ...t Pins 1 2 feeding the forward LF drivers Pins 3 4 feeding the rear LF driver Phoenix specifications and recommendations The cabinet comes with a Phoenix plug Type SPC 5 4 Push in spring connector which is already connected to the corresponding Phoenix socket of the cabinet The plug allows for direct wire connection without any tools depending on the cross section and conductor structure Technical...

Page 8: ... to 75 Hz The KSLi SUB KSLi GSUB can now be used to supplement applicable d b loudspeaker systems operated in full range mode 2 4 Technical specifications System data Frequency response 5 dB standard 36 Hz 105 Hz Frequency response 5 dB INFRA 33 Hz 75 Hz Max sound pressure 1 m free field with 40D 139 dB SPLmax Broadband signal IEC 60268 Loudspeaker data Nominal impedance front rear 4 8 ohms Power ...

Page 9: ...KSLi SUB cabinet dimensions in mm inch The same dimensions apply to the KSLi GSUB d b KSLi SUB KSLi GSUB Manual 1 1 en perliminary 9 ...

Page 10: ... of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 1 1 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to th...

Page 11: ...D2733 EN 01 01 2020 d b audiotechnik GmbH Co KG www dbaudio com perliminary ...

Reviews: