12.5.4. GPIOs (Configuration)
Selecting «GPIOs» opens the corresponding subscreen.
Within the «GPIOs» subscreen, three input fields are provided.
Selecting the respective input field allows you to configure each
GPIO contact individually.
GPIO
Defines the corresponding GPIO contact.
Mode
Trigger/switching behavior of the corresponding
GPIO contact. It can be configured to be input or
output and it can be combined with either level (non-
latching) or edge (latching) triggering, as detailed
below.
Function
In/Out
Assigns the corresponding function (Object).
Depending on the selected GPIO mode (Input/
Output), the object list will change correspondingly,
as detailed below.
Below the input fields, all GPIOs, their assigned «Mode» and
«Function» and their «Status» are listed.
GPIO Mode
Off: The corresponding GPIO contact is disabled.
Input, level, lo: Level triggered - Lo active -
Input, level, hi: Level triggered - Hi active -
Input, edge, rising: Edge triggered - rising -
Input, edge, falling: Edge triggered - falling -
Output, level, NO: Level triggered - normally open (NO)
Output, level, NC: Level triggered - normally closed (NC)
Output, manual: Manual operation (hand control).
Mainly intended for test purposes. The «Function» input field will
become a switch («GPIO Set»
/
) to manually switch the
corresponding GPIO relay.
GPIO Function
In:
▪ Display only
Mainly intended as Debug function. Displays the status of the
respective GPIO without any assignment to Objects or Presets.
▪ Power on
▪ Channel mute (Mute Ch A ... Mute Ch D, Mute all)
▪ AmpPreset 1 ... 15
▪ Input Fallback/Input Override
Note: In connection with GPIOs both Fallback and Override
are only functional when set to «Manual» mode.
Out:
▪ Power OK
▪ Mains Voltage OK
▪ Channel error: Ch A Error ... Ch D Error, Error Ch any
(cumulative output)
▪ Channel protection: Ch A Protection ... Ch D Protection,
Protection Ch any (cumulative output)
▪ Internal Error
Indicates an internal error of the device which causes an
interruption of the audio signal. Explicitly excluded are "Load
monitoring, System check and Overvoltage or Undervoltage"
conditions/states.
d&b 10D/30D Manual 1.10 en
55
Summary of Contents for 10D
Page 1: ...xD 10D 30D Manual 1 10 en ...
Page 36: ...Device setup access chart Hierarchy level 12 Device setup d b 10D 30D Manual 1 10 en 36 ...
Page 60: ...Channel setup access chart Hierarchy level 13 Channel setup d b 10D 30D Manual 1 10 en 60 ...
Page 92: ...D2026 EN 01 04 2018 d b audiotechnik GmbH www dbaudio com ...