The greenhouse should be serviced in the winter period. The greenhouse has 

durability under the action of snow loads way more than is required for greenhouses, 
but less for some snow areas in comparison with the general construction standards. 
According to SNiP 2.10.04-85 «Greenhouses and seedbeds» «weight of snow blanket 
on  1  m2  of  horizontal  surface  of  the  ground  in  design  of  static  greenhouses…» 
should be taken from 10 to 40 kg/m2 depending on a snow region. This is much 
less than the general construction standards for snow load, because it is assumed 
that on the current greenhouses a snowcap is not preserved until the next snowfall. 
According to the results of strength tests the limits of durability of the greenhouse 
frame are revealed: destroying snow load is 240 kg/m2, permissible load (with safety 
coefficient  1.4)  –  180  kg/m2.  The  permissible  load  approximately  corresponds  to 
the thickness of fresh snow 0.9 m and settled snow 0.45 m.

If the greenhouse is not heated in winter, or it is supposed to use the greenhouse 

as  an  unheated  housing,  awning,  warehouse,  etc.,  it  is  necessary  to  control  the 
snowcap  (to  shift  the  snow  down  with  a  wooden  or  plastic  scraper,  installed  on  a 
pole).  For these variants of operation it is possible to supply reinforced frames with 
a  reduced  interval  between  the  power  arcs  under  the  snow  load  specified  by  the 
customer.

Do not allow damage to the frame, and if it happened, then hold timely repairs.

Extra package insert

Ridge shape

1

2,10

Top draw band

1

8,42

Bottom draw band

2

0,60

Top arc base sheet

2

1,67

Bottom arc base sheet

2

2,91

Outermost base sheet for a runner

2

2,04

Tingle

20

0,09

Main shape

2

2,10

Washer 32х6

12

Bolt М6х14

34

Bolt М6х20

12

Bolt М6х60

2

Nut М6

48

Washer 6

50

Double-size scotch tape

1

5 м

Тable    4

1. The manufacturer bears responsibility for the greenhouse frame complete 

setup.

 2. The manufacturer bears responsibility for the greenhouse
  assemblability in accordance with the manual.
3. The manufacturer bears responsibility for the greenhouse durability under 

specified magnitude of atmospheric actions.

4. Claim presentation period is 12 months from the date of purchase.

 WARRANTY LIABILITIES 

Warranty conditions

Warranty liabilities do not apply to cases of:
1. Greenhouse installation with violation of requirements of the manual.
2. Violation of the rules of operation.
3. Inappropriate use of the greenhouse.
4. Floods, hurricanes and other natural disasters.

It is not allowed to install the greenhouse without fastening on the ground because 

of the large sail area of the greenhouse and the possibility of floating away the 

unfastened greenhouse.

Cleaning and washing of polycarbonate sheets.

1. Rinse sheet with warm water.
2. To remove dirt, wash it with mild soap solution or domestic detergent using a soft 
cloth or sponge.
3. To remove water, rinse the sheet with cold water and wipe it with a soft cloth.

Never  use  abrasives  or  high-alkali  detergents  for  cleaning 
polycarbonate  sheets.  Dry  wiping  damages  covering  layer  of 
the  covering  and  shortens  its  service  life.  Never  rub  surface  of 
polycarbonate sheets with a brush, metalized fabric or other abrasive 
materials.

       Do not use sulphur cartridges for disinfecting greenhouse 
                       against fungal and bacterial agents in order to prevent 
                       corrosion (darkening) of the frame.

The manufacturer reserves the right for greenhouse engineering design changes.

Summary of Contents for TITAN Peak 240 5,0

Page 1: ...for Greenhouse TITAN Peak 240 5 0 Manual 17 02 2020...

Page 2: ...any length multiple of 2 1 min 4 2 m width 5 0 m height 3 6 m...

Page 3: ...GE TITAN Peak 240 90 75 2800 10 5 3 PACKAGE TITAN Peak 240 90 120 1990 32 36 4 PACKAGE TITAN Peak 240 90 65 2360 11 12 5 PACKAGE TITAN Peak 240 90 70 2720 17 10 6 PACKAGE TITAN Peak 240 90 55 1145 2 6...

Page 4: ...26 End seal 1 19 9 PACKAGE TITAN Peak 240 Outermost ridge 2 2 1 able 3 DETAILED PARTS LIST INSERT marking name quantity pcs length m 1 PACKAGE INSERT 20 Ridge arc 2 1 76 4 Arc 2 3 1 2 PACKAGE INSERT...

Page 5: ...tom arc base sheet 2 2 91 Outermost base sheet for a runner 2 2 04 Tingle 20 0 09 Main shape 2 2 10 Washer 32 6 12 Bolt 6 14 34 Bolt 6 20 12 Bolt 6 60 2 Nut 6 48 Washer 6 50 Double size scotch tape 1...

Page 6: ...ding outside of the greenhouse in front the door d e l b m e s s a s i e s u o h n e e r g e h T s e r u g i f n i n w o h s d n a d e r e t t e l e r a s t i n u y l b m e s s A by means of bolts of...

Page 7: ...1 1 5 5 5 4 3 9 10 4 4 4 2 2 2 2 2 2 26 26 11 ONE INSERT extends the greenhouse by 2 13 m Number of the inserts for the greenhouse is not limited Fig 1 GENERAL VIEW OF THE GREENHOUSE FRAME WITH EXTEN...

Page 8: ...al view of the end wall angle 11 10 9 sunken screw 6 10 Determine the places of installation of angles in accordance with fig 1 8 and install the angles together with the strip 11 10 9 Strips with the...

Page 9: ...st side walls of shapes of arcs 4 until the next operation bolt angle fig 4 2 Installation of longitudinal stiffness side braces STAGE 4 Fig 4 1 2 STAGE 3 Assembly of the power arc Assembly of the pow...

Page 10: ...tical position on the prepared place 200 2042 2132 L 4084 2132 N 2132 2042 fig 5 1 Fig 5 2 5000 200 84 100 200 200 45 42 100 N number of sections of the greenhouse excluding end sections ref p 2 2 STA...

Page 11: ...embly The gate is assembled in the same way Joints are shown in the figures Strips and other surface mounted components are installed after the main shape parts are assembled STAGE 7 13 12 14 12 13 sc...

Page 12: ...0 cutting line 1490 1490 Install honeycomb polycarbonate with a specified side facing outwards sunward this side has a covering layer make sure to clarify it on buying or prior to installation Coverin...

Page 13: ...the end to the angles with the use of washers and self tapping screws fig 8 2 Places of fastening of pieces of covering to each other with the use of a permanent polycarbonate connecting shape are sho...

Page 14: ...gles on arcs 2430 2430 2 1 0 0 nut 6 Ridge shape bolt 6 20 big arc base shee small arc base sheet washer 32 6 Do not tighten up 2 3 5 0 double size scotch bolt 6 14 outermost base sheet for a runner o...

Page 15: ...raw band nut 6 washer 6 bolt 6 60 washer 6 bend the ends of the tingle after tightening of the draw band Top draw band bottom draw band ase sheet for a runner main shape bolt 6 14 Top draw band tingle...

Page 16: ...0 germany dancover com Switzerland 0840 000125 schweiz dancover com France 0975 181 800 france dancover com Austria 0662 626935 austria dancover com Sweden 040 233 262 sverige dancover com Finland 0 9...

Reviews: