background image

8

Indicator Light Function:

Power Light (Green): 

When the unit is first connected to an electrical outlet,  
the (green) power light starts to flash and continues to
flash until the “on/off” button is pressed. When the “on/off”
button is activated, the flashing (power) light turns to a
steady state “on” condition. The dehumidifier will
automatically default to the factory default setting. (See
Factory Default Setting for details)

IMPORTANT NOTE:

Depending on the humidity

conditions of the surrounding environment, the
dehumidifier may not start automatically when the “on/off”
button is pressed.(see dehumidifier operating instructions
for details)
In the event of a power failure, the unit will not re-start
automatically when power is restored. To re-start the unit
you must press the "on/off" keypad again.

Water Full Indicator Light (Red): 

When the water tank is full and /or incorrectly positioned
inside the cabinet, the (water full) red light turns on and
remains on until such time the tank is emptied and/or
correctly re-positioned. This condition will result in the
immediate shut down of the dehumidifying system. (both
compressor and fan motor operation are terminated) This
is a safety feature. When the water tank is emptied and/or
correctly re-positioned, the dehumidifier will resume
operation automatically. 

NOTE: It may take several

minutes before operating conditions resume.

Factory Default Setting:

Each time the unit is disconnected/re-connected and/or in
the event of a power failure, the electronic circuit board
automatically defaults to the following factory setting.

Humidity Setting: 60%
Fan Speed: 

Low

NOTE:

In the event of a power failure, all previous settings

are automatically erased/cancelled. If your program
setting was different than the above (default setting) it will
be necessary to re-program your settings. When the unit
is switched "Off” manually  (using the on/off keypad) the
unit will always default to the last program setting that
was used.

Water Tank  Operation:

Proper installation of the water tank is crucial in
maintaining reliable dehumidifier operation.
The water tank holds accumulated condensed water and
by means of a safety switch controls both the water level
and operation of  the dehumidification process.
i.e. When the water tank is full and/or accidentally
displaced inside the cabinet, the float switch actuator
(inside the tank) breaks contact with the safety switch.
This condition results in the immediate shut down of the
compressor and fan motor system, preventing moisture
from being condensed. 

IMPORTANT:

Never tamper with or attempt to defeat the

water level (safety) float switch system.

Operating Instructions

Circuit d’alimentation électrique - Spécifications

1.  Tout câblage doit être réalisé par un électricien

qualifié, en conformité avec les prescriptions des
codes national et local régissant les installations
électriques. Pour toute question au sujet des
instructions qui suivent, contacter un électricien
qualifié.

2.  AVANT l’installation et AVANT l’utilisation de cet

appareil, contrôler les caractéristiques de la source
d’électricité, et résoudre tout problème affectant le
câblage.

3.  Pour la sécurité et la protection des utilisateurs, cet

appareil est relié à la terre lorsqu’il est branché sur
une prise de courant de même configuration que la
fiche de branchement. En cas de doute quant à la
qualité de la liaison à la terre de la prise de courant,
consulter un électricien qualifié. 

NE JAMAIS

UTILISER UN CÂBLE DE RALLONGE NI UN
ADAPTATEUR SI LA CONFIGURATION DE LA
FICHE DE BRANCHEMENT NE CORRESPOND PAS
À CELLE DE LA PRISE DE COURANT.

4.  La plaque signalétique de l’appareil est située sur la

paroi arrière du compartiment du réceptacle à eau; on
y trouve les caractéristiques électriques et techniques
spécifiques de cet appareil.

5.  Pour éviter les risques de dommage corporel, on doit

toujours débrancher l’appareil de la source d’électricité
avant d’entreprendre des travaux de nettoyage ou
d’entretien.

16

Capacité de déshumidification (Pintes/Litres)

25/11.8

Alimentation électrique

115 Volts / 60 Hz 

Consommation d’énergie (watts)

490

Demande de courant nominale

• Déshumidification

4.5

Débit de circulation d’air maxi (pieds cubes par minute)

118

Type de réfrigérant

R22

Capacité du réceptacle à eau (litres)

5 / 10.55

Niveau de bruit en fonctionnement (dB A)

50

Dimensions (largeur/hauteur/profondeur)

13-3/8 x 19-15/16 x 10

Poids net (kg/lb)

14.5/32

NOTE:

Les spécifications sont sujettes à modification sans préavis (pour l'amélioration des produits).

Spécifications de l’appareil:

DDR2506

Summary of Contents for Diplomat DDR2506

Page 1: ...EHUMIDIFIER Table of contents 1 DÉSUMIDIFICATEUR PORTATIF Table des matières 13 Danby Products Limited Guelph Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45840 Version 1 02 06 CAUTION Read complete installation and operating instructions before installing and or using the dehumidifier ATTENTION Lire attentivement les consignes de sécurité et les instructions d utilisation avant l ut...

Page 2: ... non avenues EXCLUSIONS En vertu de la présente il n existe aucune autre garantie condition ou représentation qu elle soit exprimée ou tacite de façon manifeste ou intentionnelle par Danby Products Limitée Canada ou Danby Products Inc E U d A ou ses distributeurs agréés De même sont exclues toutes les autres garanties conditions ou représentations y compris les garanties conditions ou représentati...

Page 3: ...ecifications 4 Installation 5 Features and Unit Parts Identification 6 Key Pad Functions 7 Operating Instructions 8 Direct Drain Instructions 10 Care and Maintenance and Trouble Shooting Guide 11 Warranty 12 1 Table Of Contents Entretien MISE EN GARDE On doit toujours débrancher le cordon d alimentation de la prise de courant électrique avant d entreprendre une opération de nettoyage ou d entretie...

Page 4: ... fermer le orifice de drainage direct avec le bouchon inclus Instruction pour Drainage Direct 2 Introduction Thank you for choosing this Diplomat appliance to provide you and your family with all of the Home Comfort requirements for your home cottage or office This Owner s Manual will provide you with valuable information necessary for the proper usage care and maintenance of your new appliance If...

Page 5: ...ctionner l appareil lorsque le filtre à air n est pas en place DÉPOSE DU FILTRE À AIR 1 Saisir la poignée du filtre le filtre glissera facilement Fig 2 2 Nettoyer parfaitement le filtre à air avec un aspirateur On peut également le laver avec de l eau tiède et un détergent doux Faire sécher parfaitement le filtre avant de le réinstaller 3 Pour réinstaller le filtre à air réinsérer le filtre dans l...

Page 6: ...e la touche on off du clavier lors de la remise en marche ultérieure l appareil adopte automatiquement la configuration définie par le dernier programme utilisé Réceptacle à eau Il est essentiel que le réceptacle à eau soit correctement installé dans l appareil pour que le déshumidificateur fonctionne correctement L eau condensée générée par le processus de déshumidification s accumule dans le réc...

Page 7: ...eux vert éclaire durant quand Ventilateur Haut est utiliser 7 Ventilateur Bas Le lumineux vert éclaire durant quand Ventilateur Haut est utiliser 8 Indicateur Bac à eau plein Ce témoin lumineux s illuminera quand l une ou l autre des conditions suivantes existe A Quand le réservoir d eau interne n est pas correctement installé à l intérieur du cabinet B Quand le réservoir d eau interne est plein L...

Page 8: ...ommande Entrée d Air Panneau de Façade Filtre à Air Panneau Latéral Poignée Composants de l appareil Réservoir d Eau Roulettes Indicateur de Niveau d Eau 6 Soft Touch Electronic Control Key Pads Auto Sensing Humidity Control Adjustable Humidity Settings 35 80 2 Fan Speed Settings High Low Delay Start Protection compressor Auto Defrost De Icier Full Bucket Indicator Light Easy Roll Casters 4 Front ...

Page 9: ...ions To view the Set Operating Relative Humidity Value 2 press the up or down button once and the set RH operating value will flash for approximately 5 seconds in the LED window then revert back to display the internal room environment RH value 2 ON OFF Button Each time this button is pressed the unit turns On adjacent indicator light illuminates or Off adjacent indicator light is not illuminated ...

Page 10: ...both the water level and operation of the dehumidification process i e When the water tank is full and or accidentally displaced inside the cabinet the float switch actuator inside the tank breaks contact with the safety switch This condition results in the immediate shut down of the compressor and fan motor system preventing moisture from being condensed IMPORTANT Never tamper with or attempt to ...

Page 11: ...équate par un électricien qualifié Si les caractéristiques de la source d alimentation électrique de la résidence ne correspondent pas aux spécifications ci dessus ou en cas d incertitude quant à la qualité de la liaison à la terre demander à un électricien qualifié ou à la compagnie de distribution d électricité d inspecter l installation électrique et d effectuer tout travail correctif nécessair...

Page 12: ...ens et animaux ne peuvent pas réagir rapidement Un appareil défaillant peut susciter une surchauffe extrême résultant à un accident avec blessures personnelles et les damages de propriété 10 Direct Drain Feature This dehumidifier is inclusive of a direct drain feature located at the rear of the cabinet NOTE The drain hose is not included with the unit The direct drain feature is intended for use i...

Page 13: ...nt very low Check all doors and windows are closed Area room is too large for the capacity of the dehumidifier PROBLEM POSSIBLE CAUSE Unit will not operate Dehumidifying capacity moisture removal low Relative Humidity setting not reached after long period of operation 11 Storage When the dehumidifier is not being used for long time periods please follow these instructions 1 Disconnect the power co...

Page 14: ...rranty shall be at an end EXCLUSIONS Save as herein provided Danby Products Limited Canada or Danby Products Inc U S A there are no other warranties conditions representations or guarantees express or implied made or intended by Danby Products Limited or its authorized distributors and all other warranties conditions representations or guarantees including any warranties conditions representations...