background image

Consignes d’utilisation

USING THE REMOTE
CONTROLLER
BUTTONS

1

ON/OFF

MODE

TEMP

UP

TEMP

DOWN

ENERGY

TIMER

CLEAN

AIR

SLEEP

S

SAVER

FAN

TIMER OPERATION
To set the Auto-start time.

1)

Push the TIMER button when the unit is

operational, only the Auto-stop feature
can be set.

2)

Keep pressing the TIMER button, each

press will increase the selected time by
1 hour increments, up to 12 hours.

3)

The time can be set in a range of 0~12

hours.

4)

After the desired time has established,

wait for about 10 seconds until the
setting temperature reverts back in the
display window of the air conditioner.
This indicates the program is set.

NOTE:

To cancel the TIMER setting, push the TIMER button until 0 hour is
displayed on the LCD window of the air conditioner.

1

ON/OFF

MODE

TEMP

UP

TEMP

DOWN

ENERGY

TIMER

CLEAN

AIR

SLEEP

S

SAVER

FAN

CLEAN AIR OPERATION

When this button is pressed, the ion gener-
ator is energized and will help remove
pollen and impurities from the air. Press it
again to stop the operation.

1

ON/OFF

MODE

TEMP

UP

TEMP

DOWN

ENERGY

TIMER

CLEAN

AIR

SLEEP

S

SAVER

FAN

ENERGY SAVER OPERATION

In this mode, the fan will continue to
run for 3 minutes after the compressor
shuts off. The fan then cycles on for 2
minutes at 10 minute intervals until the
room temperature is above the set
temperature, at which time the compressor
turns back on and cooling stars.

29

Summary of Contents for DAC6011E

Page 1: ...ted Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45840 Model Mod le Modelo Owner s Use and Care Guide Guide d utilisation et soins de Propri taire AIR CONDITIONER CLIMATISEUR V1 11 10 DM...

Page 2: ...ation initiale de ce produit CLIMATISEUR Guide d utilisation et d entretien Bienvenue Consignes de S curit Importantes Caract ristiques Installation Consignes d utilisation Soins et Entretien D pannag...

Page 3: ...For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following information located on the manufacturers nameplate on the rear panel of the unit N...

Page 4: ...rough the power cord plug when plugged into a matching wall outlet If you are not sure whether your wall outlet is properly grounded please consult a qualified electrician 5 The wall outlet must match...

Page 5: ...FIlter Exterior Air Inlet Cabinet Interior Air Inlet Control Panel Interior Air Outlet Installation Instructions CAUTION Because the compressor is located on the controls side of the unit left side t...

Page 6: ...30 above the floor or ground Curtains and other objects within a room should be prevented from blocking the air flow E Be certain the proper electrical outlet is within reach of the installation Use...

Page 7: ...Cabinet Extend the shutter from the shutter frame and slide it into the shutter tabs on the side channel of the air conditioner as shown in Fig 4 Slide the shutters into the top L Shaped and bottom U...

Page 8: ...the frames to the window sash using one 3 4 screw on each side and one in the L shaped mounting bracket Fig 5 Secure the shutter clamp on each side of the lower shutter and secure to window sill using...

Page 9: ...operation SLEEP MODE When activated the current set temperature is gradu ally increased over a one 1 hour period then maintained for seven 7 hours Once the program is complete the air conditioner will...

Page 10: ...indoor unit Prevent any liquid from falling into the remote controller Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to d...

Page 11: ...tion is available on COOL HEAT or AUTO mode only and maintain the most comfortable temperature for you REMOTE CONTROLLER BUTTONS ON OFF MODE TEMP UP TEMP DOWN SWING TIMER SLEEP FAN ON OFF button TEMP...

Page 12: ...FAN COOLING HEATING FAN OPERATION Ensure the unit is plugged in and power is available 1 Press the ON OFF button to start the air conditioner 2 Press the MODE button to cool heat cooling and heating...

Page 13: ...fore it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time durin...

Page 14: ...itioner This indicates the program is set NOTE To cancel the TIMER setting push the TIMER button until 0 hour is displayed on the LCD window of the air conditioner 1 ON OFF MODE TEMP UP TEMP DOWN ENER...

Page 15: ...ed by a cover Remove the button cell according to the arrow marked at the back of the remote controller 1 Slightly press A position according to the number 1 arrow direction by your forefinger 2 Press...

Page 16: ...y hand in warm water Dry thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results...

Page 17: ...utside Hot and humid weather Condensation run off is normal under these conditions 6 Water dripping inside Unit is not properly angled to allow water to drain outside Unit must be installed on an angl...

Page 18: ...t Danby will be responsible or liable for any spoilage or damage to food or other contents of this appliance whether due to any defect of the appliance or its use whether proper or improper EXCLUSIONS...

Page 19: ...la plaque signal tique du fabricant sur le c t droit de l appareil au dessus du cordon d alimentation Vous aurez besoin de ces renseignements si vous contactez un repr sentant du Service la client le...

Page 20: ...e dans une prise murale qui lui correspond Si vous n tes pas certain que votre prise de courant murale est mise la masse ad quatement veuillez consulter un lectricien qualifi 5 La prise murale doit co...

Page 21: ...xternes sont suffisamment froides placer le climatiseur hors de service et utiliser le MODE DE VENTILATEUR la position HAUTE MOYENNE ou BAS Ceci fait circuler l air l int rieur de la pi ce pour fourni...

Page 22: ...auvent pour prot ger l unit D Laissez suffisamment d espace libre autour du caisson pour permettre une ample circulation d air travers l appareil Voir Fig 2 L arri re de l appareil doit donner sur l...

Page 23: ...e de canaux sup rieur sur le caisson Pr install sur certain mod les Canal sup rieur en forme de L Installez le canal en forme de L au dessus du caisson tel que montr la Fig 3 un utilisant quatre 4 vis...

Page 24: ...s volets compl tement de chaque c t et fixez le haut des structures au cadre de la fen tre en utilisant une vis de 3 4 po et une rondelle de s curit sur chaque c t Fig 5 Coupez la bande mousse adh sif...

Page 25: ...ommeil Le mode de sommeil augmentera votre temp rature de cli matisation pr r gl e graduellement pendant une p riode de un 1 heures la nouvelle temp rature est maintenue pendant sept 7 heures Une fois...

Page 26: ...e indoor unit Prevent any liquid from falling into the remote controller Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to...

Page 27: ...is available on COOL HEAT or AUTO mode only and maintain the most comfortable temperature for you REMOTE CONTROLLER BUTTONS ON OFF MODE TEMP UP TEMP DOWN SWING TIMER SLEEP FAN ON OFF button TEMP UP bu...

Page 28: ...FAN COOLING HEATING FAN OPERATION Ensure the unit is plugged in and power is available 1 Press the ON OFF button to start the air conditioner 2 Press the MODE button to cool heat cooling and heating...

Page 29: ...efore it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time duri...

Page 30: ...itioner This indicates the program is set NOTE To cancel the TIMER setting push the TIMER button until 0 hour is displayed on the LCD window of the air conditioner 1 ON OFF MODE TEMP UP TEMP DOWN ENER...

Page 31: ...ed by a cover Remove the button cell according to the arrow marked at the back of the remote controller 1 Slightly press A position according to the number 1 arrow direction by your forefinger 2 Press...

Page 32: ...FILTRE AIR 1 Utilisez un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneus...

Page 33: ...nt de la condensation est normal quand le temps est chaud et humide Ajoutez un tube flexible pour r acheminer l coulement de l eau 6 De l eau s goutte l int rieur L appareil n est pas inclin ad quatem...

Page 34: ...ondition ou repr sentation qu elle soit exprim e ou tacite de fa on manifeste ou intentionnelle par Danby ou ses distributeurs agr s De m me sont exclues toutes les autres garanties conditions ou repr...

Page 35: ...call the TOLL FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description CLIMATISEUR Le num ro de mod le se...

Reviews: