3
Application Notes
I. Always make sure power is off before attempting to work on or near the actuator and its electrical controls.
2. Electrak 10 actuators are load protected with a slip clutch. The clutch will slip when the load exceeds the
actuator’s rating, preventing any movement of the load. The clutch is factory set based on load rating.
3. The duty cycle for the Electrak 10 actuator is 25% “on time”. For instance, an actuator operating for 25 seconds
must remain off for 75 seconds before operating again. Exceeding this maximum will cause the motor to overheat
and trip its internal thermal breaker.
4. Electrak 10 actuators are weather protected for use in outdoor applications, but they are not waterproof and
should not be used in underwater conditions
5. Electrak 10 actuators are not explosion or dust ignition proof; do not use in those types of environments.
6. Electrak 10 actuators are factory lubricated for life. No disassembly is ever required for routine maintenance
purposes.
Specifications
Stroke Length:
4, 8 or 12”
Duty Cycle:
Twenty-five percent “on” time at 75° F at rated load (higher duty cycles at lower loads)
Life:
20,000 cycles, nominal
Motor Protection:
Automatically reset thermal overload protection.
Temperature Range:
-150F to +150° F
End Play:
.070 inch maximum
Overload Protection:
Mechanical load limit clutch
Mounting:
Actuator ends must be restrained from rotating (to counter 90 in-lb maximum torque
developed) and mounted with parallel pins equally supported on both ends. Actuator
not to be mounted off of cover (outer) tube.
Lead Wires:
14 AWG PVC, 800C insulation
Static Loads:
3000 lbs. maximum
Dynamic Loads:
Summary of Contents for THOMSON D12-05B5