Dametric AB
CMD-DM2
Manual
CMD-DM2 Manual EN.docx
Nov. 21, 2019
Page 5 of 5
6
Installation
The DCM-DM2 is normally installed into
a step motor drive unit, CMU-2X. If the
unit is used alone then follow the
installation description below.
All electrical connections uses the J1
detachable plinth.
Peel of the insulation
app. 10 mm from the
wire end.
Use a small screw driver to unload the
spring connector and then insert the wire.
6.1 Power supply
1
+24VDC
Power supply to the module
3
0VDC
Power ground
6.2 Step motor cable
5
SM-WA1
To control motor winding
7
SM-WA2
To control motor winding
9
SM-WB1
To control motor winding
11
SM-WB2
To control motor winding
6.3 Control I/O
13
DI-CLOSE
Close plates
14
DI-OPEN
Open plates
15
DI-HISPEED Move at high speed
15
DO-ALARM Alarm output
7
Contact
Sales, development, production and service:
Dametric AB
Jägerhorns Väg 19, 141 75 Kungens Kurva, Sweden
Phone: +46-8 556 477 00
e-mail:
Web site:
www.dametric.se
dametric
CMD-DM2
J1
CMD-DM2
A+
A-
B+
B-
GND
J3/5
J3/7
J3/9
J3/11
J3/12
CM-2NM...
Step
motor
A+
A-
B+
B-
GND
1
2
3
4
GND
K-CM25K
1
2
19
20