background image

Dametric AB 

CMD-DM2 

Manual 

CMD-DM2 Manual EN.docx 

Nov. 21, 2019 

Page 4 of 5 

Use of the buttons. 
For the base level: 
MENU (short)  Returns to the base level of the chosen function. 
MENU (>1s) 

Returns to the basic display indication. 

NEXT 

Step to the next function. 

PREV 

Step to the previous function. 

PLUS 

Starts the parameter-level for the chosen function or steps to the next level. 

PREV 

Step to the previous parameter level. 

ENT 

No function. 

For the parameter-level: 
MENU (short)  Returns to the base level of the chosen function. 
MENU (>1s) 

Returns to the basic display indication. 

NEXT 

Step to the next digit during edit. 

PREV 

Step to the previous digit during edit. 

PLUS 

Increase the digit one step. 

MINUS 

Decrease the digit one step. 

ENT (short) 

Toggle between select mode (sel.) and edit mode (edit) for the chosen parameter. 

ENT (>1s) 

Saves the parameter to the EERPOM-memory. 

The list below shows the functions and parameters. 
Use buttons NEXT and PREV to step between the functions (bold text). 
Then select a parameter for the chosen function with the PLUS and MINUS buttons.  

5.2.2  Parameters 

CMD Screw pitch

  

Set this parameter according to the thread of the actual adjusting screw in mm/turn.  

CMD Low speed

 

Set the speed when running at low speed. The default value is 0.05 mm/s. 

CMD High speed

 

Set the speed when running at high speed. The default value is 0.25 mm/s. 

CMD Direction

 

Set the direction. Alternate between 0 and 1 to get the desired rotation direction. 

CMD Drive curr.

 

Set the drive current. The default value is 1.0A. 

CMD Hold curr.

 

Set the hold current. The default value is 0.2A. 

CMD Status

 

Indicates the working status of the step motor. 

CMD Run current

 

Shows the actual current consumption (used for troubleshooting). 

 

 