Dametric AB
CMD-DM2
Manual
CMD-DM2 Manual EN.docx
Nov. 21, 2019
Page 4 of 5
Use of the buttons.
For the base level:
MENU (short) Returns to the base level of the chosen function.
MENU (>1s)
Returns to the basic display indication.
NEXT
Step to the next function.
PREV
Step to the previous function.
PLUS
Starts the parameter-level for the chosen function or steps to the next level.
PREV
Step to the previous parameter level.
ENT
No function.
For the parameter-level:
MENU (short) Returns to the base level of the chosen function.
MENU (>1s)
Returns to the basic display indication.
NEXT
Step to the next digit during edit.
PREV
Step to the previous digit during edit.
PLUS
Increase the digit one step.
MINUS
Decrease the digit one step.
ENT (short)
Toggle between select mode (sel.) and edit mode (edit) for the chosen parameter.
ENT (>1s)
Saves the parameter to the EERPOM-memory.
The list below shows the functions and parameters.
Use buttons NEXT and PREV to step between the functions (bold text).
Then select a parameter for the chosen function with the PLUS and MINUS buttons.
5.2.2 Parameters
CMD Screw pitch
Set this parameter according to the thread of the actual adjusting screw in mm/turn.
CMD Low speed
Set the speed when running at low speed. The default value is 0.05 mm/s.
CMD High speed
Set the speed when running at high speed. The default value is 0.25 mm/s.
CMD Direction
Set the direction. Alternate between 0 and 1 to get the desired rotation direction.
CMD Drive curr.
Set the drive current. The default value is 1.0A.
CMD Hold curr.
Set the hold current. The default value is 0.2A.
CMD Status
Indicates the working status of the step motor.
CMD Run current
Shows the actual current consumption (used for troubleshooting).