37
Calibration Numbers for Variable Rate Ready Spreaders
*For 360 Pulse Encoder*
063-0173-937
Inches of belt travel per revolution of rear roller = 13”
Encoder pulses per revolution of rear roller = 180
Gate Width = 8”
Gate Height = Actual inches above the floor (chain is ½” thick)
Meter Cal = Product Density
Speed Cal w/ Sky Trak = 600
Speed Cal w/Astro II = 783
Spreader Constant #’s
2” Gate Height = 3000
2.5” Gate Height = 2392
3” Gate Height = 1988
3.5” Gate Height = 1714
4” Gate Height = 1494
4.5” Gate Height = 1328
5” Gate Height = 1200
*The spreader constant is entered by holding down the meter cal. button until the spreader constant
menu comes available.
*These numbers are a good starting point and may be need to be adjusted slightly if your actual rate is
off.
Summary of Contents for MOBILITY 800
Page 17: ...15 60 SPREAD ...
Page 18: ...16 90 SPREAD ...
Page 19: ...17 60 to 90 SPREAD VARIABLE RATE ...
Page 45: ...43 NOTES ...
Page 46: ...www daltonag com 602 E VAN BUREN LENOX IOWA 50851 800 342 7498 ...