Spyder3 GigE Vision User Manual
03-032-20027-02
DALSA
10
Tap
1
CCD
Readout
Shift
Register
CCD
Readout
Shift
Register
N
Pixels
(14
μ
m
x
14
μ
m)
N
Pixels
(14
μ
m
x
14
μ
m)
N
=1024,
2048
Pixel
1,
1
Sensitivity Mode and Pixel Readout
The camera has the option to operate in either high sensitivity or low sensitivity mode or
in tall pixel mode.
When in high sensitivity mode, the camera uses both line scan sensors and its
responsivity increases accordingly. When in low sensitivity mode, the camera uses the
bottom sensor. When operating in tall pixel mode, the camera operates using both
sensors, creating a 28µm x 14µm pixel.
The sensitivity mode is software controlled through QuickCam GEV, through the
GenICam feature
SensitivityMode
.
Figure 3: High Sensitivity Mode
In high sensitivity mode, the camera uses either a 14µm x 14µm pixel (1k and 2k models)
or a 10µm x 10µm pixel (4k model) and captures the same image twice, resulting in a
brighter image.
CCD
Readout
Shift
Register
CCD
Readout
Shift
Register
Sensor
2(14
μ
m
x
14
μ
m
OR
10
μ
m
x
10
μ
m)
Sensor
1
OR
(14
μ
m
x
14
μ
m
10
μ
m
x
10
μ
m)
14/10
μ
m
Pixel Detail
14/
10
μ
m
14/
10
μ
m
Figure 4: Low Sensitivity Mode
In low sensitivity mode, the camera uses either a 14µm x 14µm pixel (1k and 2k models)
or a 10µm x 10µm pixel (4k model) and captures the image using one sensor (Sensor 1).
Summary of Contents for Spyder3 SG-11-01k40-00-R
Page 14: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 14 ...
Page 30: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 30 ...
Page 82: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 82 ...
Page 88: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 88 ...
Page 90: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 90 ...