Spyder3 SC-34 Color Camera User's Manual
17
Teledyne DALSA
03-032-20116-01
2.2 Camera LED
The cam era is equ ip p ed w ith a red / green LED u sed to d isp lay the op erational statu s of the cam era. The
table below su m m arizes the op erating states of the cam era and the corresp ond ing LED states.
When m ore than one cond ition is active, the LED ind icates the cond ition w ith the highest p riority. Error
and w arning states are accom p anied by corresp ond ing m essages fu rther d escribing the cu rrent cam era
statu s.
Table 7: Diagnostic LED
Priority
Color of Status LED
Meaning
1
Flashing Red
Fatal Error. For exam p le, cam era tem p eratu re is too high and cam era
therm al shu td ow n has occu rred .
Warning. Loss of fu nctionality (e.g. external SRAM failu re).
2
Flashing Green
Cam era initialization or execu ting a long com m and
3
Solid Green
Cam era is op erational and fu nctioning correctly
4
Solid Red
Warning. Loss of fu nctionality.
2.3 Camera Link Data Connector
Figure 9: Camera Link MDR26 Connector
The Cam era Link interface is im p lem ented as Base Configu ration in the Sp yd er3 Color cam eras.
Table 8: Camera Link Hardware Configuration Summary
Configuration 8 Bit Ports
Supported
Serializer
Bit Width
Number
of Chips
Number of
MDR26
Connectors
Applicable
Camera
Models
Base
A, B, C
28
1
1
All m od els
Table 9: Camera Link Connector Pinout
Base Configuration
One Channel Link Chip + Camera C Serial Communication
Camera Connector Right Angle Frame Grabber
Channel Link Signal
1
1
inner shield
14
14
inner shield
2
25
X0-
15
12
X0+
3
24
X1-
16
11
X1+
4
23
X2-
17
10
X2+
**3M part 14X26-SZLB-XXX-0LC is a complete
cable assembly, including connectors.
Unused pairs should be terminated in 100
ohms at both ends of the cable.
All manuals and user guides at all-guides.com