Piranha4 4K Color Camera User's Manual
69
Teledyne DALSA
03-032-20180-01
On
On
FPN and flat field coefficients
enabled .
DFN C
Initialize
Initialize
Reset all FPN to 0 and all flat
field coefficients to 1.
ScanDirectionControlled ScanDirectionControlled
Different u ser set load ed
d ep end ing on d irection .
Select flatfield
Correction Scan
Direction Reverse Set
flatfield ScanDirectionReverseSet
When flatfield CorrectionMod e is
set to ScanDirectionControlled
this featu re selects the UserSEt (1
to 8) w hich w ill be u sed for the
reverse scan d irection.
1.00
Beginner
DFN C
Calibration Algorithm
flatfield CorrectionAlgorithm
Selection betw een tw o d ifferent
flat field algorithm s.
1.00
Beginner
DFN C
Basic
Basic
Direct calcu lation of coefficients
based on average line valu es and
target. First each color is flat
field ed to its p eak valu e and
then the color gains are u sed to
achieve the target.
Low Pass
Low Pass
A low p ass filter is first ap p lied
to the average line valu es before
calcu lating the coefficients. Use
this algorithm if the calibration
target is not u niform ly w hite or
it is not p ossible to d efocu s the
im age. Becau se of the low p ass
filter this algorithm is not able to
correct p ixel-to-p ixel variations
and so it is p referable to u se the
―Basic‖ algorithm.
Calibration Target
flatfield CalibrationTarget
Set a valu e betw een 0 and 255 to
w hich the flat field algorithm
w ill taget the im age to.
1.00
Beginner
DFN C
Calibration Sam p le Size
Lines_2048
Lines_4096
flatfield CalibrationSam p leSize
Lines_2048
Lines_4096
Sets the nu m ber of lines to be
averaged d u ring a flat field
calibration
1.00
Beginner
DFN C
ROI Offset X
flatfield CalibrationROIOffsetX
Set the starting p oint of a region
of interest w here a flat field
calibration w ill be p erform ed
1.00
Beginner
DFN C
ROI Wid th
flatfield CalibrationROIWid th
Sets the w id th of the region on
interest w here a flat field
calibration w ill be p erform ed
1.00
Beginner
DFN C
Calibrate FPN
flatfield CalibrationFPN
Initiates the FPN calibration
p rocess
1.00
Beginner
DFN C
Calibrate PRN U
flatfield CalibrationPRN U
Initiates the PRN U or Flatfield
p rocess
1.00
Beginner
DFN C