76
Piranha2 User’s Manual
Code Command
Short
Form
Parameters Description
Parameters:
i
= integer
f
= float
t
= tap selector
s
= string
x1
= pixel start
number
x2
= pixel end number
[]=
optional
parameter
27
set_data_mode
sdm
i
Set the data mode of camera
output to:
0: 8-bit, A/B/C/D ports, single
processor
1: 10-bit, A/B/C and D/E/F
ports, single processor
2: 8-bit, A/B and D/E ports,
dual processor
3: 10-bit, A/B/C and D/E/F
ports, dual processor
28 set_digital_offset
sdo t
i
Subtracts the input value from
the video signal prior to the
PRNU correction. The first
parameter is the tap selection 1
to 4, 0 for all taps. The second
parameter is the offset in a
range from 0 to 511. Use in
calibrated mode only.
29
set_exposure_mode
sem
i
Set the exposure mode:
1: Internal SYNC and PRIN,
max line rate and exposure
time, factory setting
2: Internal SYNC and PRIN,
programmable line rate and
exposure time using
commands
ssf
and
set
3: External SYNC, internal
PRIN, maximum exposure
time
4: Smart EXSYNC
5: External SYNC and PRIN
6: External SYNC, internal
PRIN, programmable
exposure time
30 set_exposure_time
set f
Set the exposure time in
exposure mode 2 or 6. Value
will be a floating point number
in µsecs
31
set_fpn_coeff
sfc
i i
Set the FPN coefficient. The
first parameter is the pixel
number within the range 1 to
8192. The second value is a
specified value within the
range 0 to 127.
32 set_gain
sg t
f
Set the analog gain. The first
parameter is the tap selection 1
to 4, 0 for all taps. The second
parameter is a gain value
specified from –10 to 10. A
03-32-00493-11
DALSA