10
•
Linea HS Multifield Camera
Full Well
25,000 e
-
Typical
PRNU
< ±2%
At 50% saturation
3,4)
DSNU (FPN)
< ±2 DN
SEE
Blue 1.3 nJ/cm
2
Green 1 nJ/cm
2
Red 0.8 nJ/cm
2
At 460 nm
At 560 nm
At 660 nm
NEE
Blue 0.5 pJ/cm
2
Green 0.4 pJ/cm
2
Red 0.3 pJ/cm
2
At 460 nm
At 560 nm
At 660 nm
Integral non-linearity
< 2%
1)
Test Conditions unless otherwise specified:
o
8-bit, 1x gain
o
100 kHz line rate
o
Light source: White LED if wavelength not specified
o
Front plate temperature: +45º C
o
DN = digital number
2)
Random Noise below quantization limit cannot be measured accurately; use higher bit depth or
higher gain for comparison purposes.
3)
Calibration at 80% saturation, measurements at 50% saturation.
4)
Light sources vary spectrally and spatially: re-calibrate cameras in actual system.
5)
Specifications not guaranteed when operating in area mode.
Environmental Specifications
Table 5: Environmental Specifications
Environmental Specifications
Storage temperature range
-20 °C to +80 °C
Humidity (storage and operation)
15% to 85% relative, non-condensing
MTBF (mean time between failures)
>100,000 hours, typical field operation
Flash Memory Size
Table 6: Camera Flash Memory Size
Camera
Flash memory size
All models
4 GByte
Certification & Compliance
Table 7: Camera Certification & Compliance
Compliance