Linea HS Multifield Camera
•
23
Power and GPIO Connections
The camera uses a single 12-pin Hirose male connector for power, trigger, and strobe signals. The
suggested female cable mating connector is the Hirose model HR10A-10P-12S.
12-Pin Hirose Connector Signal Details
The following figure shows the pinout identification when looking at the camera’s 12-pin male
Hirose connector. The table below lists the I/O signal connections.
1
4
6
7
12
11
3
2
10
8
9
5
Figure 9: 12-pin Hirose Pin Numbering
Table 8: 12-pin Hirose pin assignment
Pin Number
Input / Output
Signal Details
Notes
1
Power Ground
2
+12 V to +24 V power
3
Output
Line 3 Out
0 to 3.3 V TTL
4
Output
Line 4 Out
0 to 3.3 V TTL
5
Input
Line 1/ Trigger / Phase A
0 to 3.3 V TTL
6
Input
Line 2 / Scan Direction/Phase B
0 to 3.3 V TTL
7
Output
Line 5 Out
0 to 3.3 V TTL
8
Output
Line 6 Out
0 to 3.3 V TTL
9
Power Ground
10
+12 V to +24 V power
11
Signal Ground
Note: intended as a return path for
GPIO signal and not intended as a
power ground
12
Signal Ground
Note: intended as a return path for
GPIO signal and not intended as a
power ground
The wire gauge of the power cable should be sufficient to accommodate a surge during power-up of
at least 3 amps with a minimum voltage drop between the power supply and camera. The camera
can accept any voltage b12 and +24 Volts. If there is a voltage drop between the power
supply and camera, ensure that the power supply voltage is at least 12 Volts plus this voltage drop.
The camera input supply voltage can be read using CamExpert. Refer to the section on Voltage &
Temperature Measurement for more details.