64
•
Appendix A: GenICam Commands
Linea HS Multifield Camera
Display Name
Feature
Description
Device
Version
& View
Row Selector
flatfieldCalibrationColorSelector
Specify which sensor rows to
perform PRNU calibration on, all
or individual colors.
1.00
Beginner
DFNC
Calibrate PRNU
flatfieldCalibrationPRNU
Initiates the Flat Field (PRNU)
calibration process
1.00
Beginner
DFNC
Flat Field Correction Current
Active Set
Factory Set
User set (1 thru 16)
flatfieldCorrectionCurrentActiveSet
Factory Set
User set (1 thru 16)
Selects the User PRNU set to be
saved or loaded.
Factory set can only be loaded.
Only the PRNU values are saved
or loaded which is much faster
than saving or loading the full
Factory or User set.
1.00
Guru
DFNC
Save Calibration
flatfieldCalibrationSave
Saves the User PRNU set
specified by
flatfieldCorrectionCurrentActiveSet
to the camera.
1.00
Guru
DFNC
Load Calibration
flatfieldCalibrationLoad
Loads the User PRNU set
specified by
flatfieldCorrectionCurrentActiveSet
to the camera and makes it active.
1.00
Guru
DFNC
Output LUT Mode
lutMode
Allows the output LUT to be
selected
When enabled, the same LUT is
used for all colors
1.00
Beginner
DFNC
Off
Off
The output LUT is disabled and
linear data is output
Gamma Correction
Gamma Correction
Gamma correction table is used
User Defined
User Defined
LUT download by the user is
used.
Gamma Correction
gammaCorrection
Sets the output LUT gamma
correction factor
𝐷𝐷𝐷𝐷
𝑜𝑜𝑜𝑜𝑜𝑜
= 255 ×
�
𝐷𝐷𝐷𝐷
𝑖𝑖𝑖𝑖
255
�
1
𝛾𝛾
1.00
Beginner
DFNC
Image Filter Mode
imageFilterMode
Enable image filter.
Image Filter Type
imageFilterType
Read-only: Weighted Average
Image Filter Kernel Size
imageFilterKernelType
Kernel 1x3 or 1x5
Image Filter Contrast Ratio
imageFilterContrastRatio
0 to 1