48
Operational Reference
Genie HM-HC Series-GigE Vision Camera
External Trigger Programmable Exposure
Also known as “Edge Pre-select” exposure. See the timing diagram below.
The external trigger edge initiates the exposure process. The active external trigger edge can be selected as
either the low-high or high-low transition.
The delay from active trigger edge to start of exposure is programmable from 100
μ
s to 4 seconds (1
μ
s steps) .
Supports
"
Synchronous Mode
" on page 51
timing for fastest possible frame rates. Start of exposure is aligned
on the next horizontal line while exposure duration granularity is 1µs. Exposure and sensor readout can be
concurrent.
Supports
"
Reset Mode
" on page 52
timing. Exposure granularity is 1µs. Exposure and sensor readout must be
sequential, limiting the maximal frame rate.
Exposure duration is programmable from 10
μ
s in Reset Mode or 56µs in Synchronous Mode, to 4 seconds
(with 1
μ
s steps).
Any external trigger received before the previous exposure is complete is ignored. An application can elect to
receive messages about ignored triggers. See
"
Events
" on page 71
.
Programmable Synchronous Mode Exposure Timing
Summary of Contents for Genie HM640
Page 8: ...6 Contents Genie HM HC Series GigE Vision Camera...
Page 34: ...32 Installing the Genie Camera Genie HM HC Series GigE Vision Camera...
Page 94: ...92 Operational Reference Genie HM HC Series GigE Vision Camera...
Page 98: ...96 Network Overview Tools Genie HM HC Series GigE Vision Camera...
Page 104: ...102 Sapera CamExpert Guide Genie HM HC Series GigE Vision Camera...
Page 138: ...136 Glossary of Terms Genie HM HC Series GigE Vision Camera...