54
Falcon2 4M, 8M, and 12M Camera User's Manual
03-032-20107-03
Teledyne DALSA
N ame
flatfieldCorrectionType
Disp lay N am e
Correction Type
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Exp ert
Access
Read Only
Typ e
Enu m eration
Valu es
A reaBase
N otes
Flatfield correction is based on an entire im age (array).
N ame
flatfieldCorrectionCurrentActiveSet
Disp lay N am e
Current Active Set
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Exp ert
Access
Read -Write (Read -Only w hen in Calibration Mod e)
Typ e
Enu m eration
Valu es
FactoryFlatfield
- Factory calibrated flat field . This set actu al consists of three sets calibrated for
a given p ixelInp u tSize. When the p ixelInp u tSize changes, the cam era w ill au tom atically
change the set in u se.
UserFlatField1
to
UserFlatField4
- User configu rable flat field sets. They can only be calibrated to
1 p ixelInp u tSize valu e.
N otes
Sp ecifies the cu rrent set of flat field coefficients to u se. This featu re cannot be changed w hile
the cam era is in flat field calibration m od e.
N ame
flatfieldCorrectionPixelYCoordinate
Disp lay N am e
Pixel Y Coordinate
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Exp ert
Access
Read -Write w hen in Calibration Mod e
Typ e
Enu m eration
Valu es
1 to
SensorHeight
N otes
Vertical Ind exer into the arr ay of FFC coefficients.
N ame
flatfieldCorrectionPixelXCoordinate
Disp lay N am e
Pixel X Coordinate
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Exp ert
Access
Read -Write w hen in Calibration Mod e
Typ e
Enu m eration
Valu es
1 to
SensorW idth
N otes
H orizontal Ind exer into the array of FFC coefficients.
N ame
flatfieldCorrectionGain
Disp lay N am e
Pixel Gain(PRN U)
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Beginner
Access
Read -Write w hen in Calibration Mod e
Typ e
Float
Valu es
1 to 2 (w hen flatfield CorrectionGainMod e =
HighGain
).
1 to 1.5 (w hen flatfield CorrectionGainMod e =
HighResolution
).
N otes
Sets the gain to ap p ly to the cu rrently selected p ixel.