26
Falcon2 4M, 8M, and 12M Camera User's Manual
03-032-20107-03
Teledyne DALSA
N ame
D eviceTemperature
Disp lay N am e
Temperature ( C )
N am e Sp ace
Stand ard
Firm w are Release
00
Visibility
Exp ert
Access
Read -only
Typ e
Float
Units
d egrees Celsiu s
Valu es
0 - 100 C
N otes
Dep end ing on the host ap p lication (e.g. GUI). This valu e is a p olled valu e and m ay
au tom atically be u p d ated every second . Otherw ise the valu e w ill only be u p d ated u p on
connection or w hen the tem p eratu re selector is chan ged .
N ame
D eviceUserID
Disp lay N am e
D evice User ID
N am e Sp ace
Stand ard
Firm w are Release
00
Visibility
Beginner
Access
Read -Write
Typ e
String
Valu es
e.g. ― My Camera
N otes
This featu re is au tom atically saved to the cam era's non volatile m em ory w hen it is w ritten.
N ame
UserSetD efaultSelector
Disp lay N am e
[User Set Defau lt Selector]
Pow er-up Configuration
N am e Sp ace
Stand ard
Firm w are Release
00
Visibility
Beginner
Access
Read -Write
Typ e
Enu m eration
Valu es
N one
- no d efau lt set is load ed . The cam era u ses m od el d efault valu es and no factory
calibrated valu es
Factory
- load factory calibrated d efau lts
UserSet
x
― load previously saved user set
x
(w here
x
is nu m ber betw een 1 and 4)
N otes
Selects the cam era configu ration set to load and m ake active on cam era p ow er -u p or reset.
The cam era configu ration sets are stored in cam era non -volatile m em ory.
The featu re valu e au tom atically saved to th e cam era's non -volatile m em ory w hen it is
w ritten.
N ame
UserSetSelector
Disp lay N am e
User Set Selector
N am e Sp ace
Stand ard
Firm w are Release
00
Visibility
Beginner
Access
Read -Write
Typ e
Enu m eration
Valu es
Factory
- factory calibrated d efau lts
UserSe
t
x
― previously saved user set
x
(w here
x
is nu m ber betw een 1 and 4 )
N otes
Selects the cam era configu ration set to load featu re settings from or save cu rrent featu re
settings to. The Factory set contains d efau lt cam era featu re settings. Disable d w hen
flatfieldCorrectionM ode
=
Calibration
.
N ame
UserSetLoad
Disp lay N am e
User Set Load
N am e Sp ace
Stand ard
Firm w are Release
00
Visibility
Beginner
Access
Read -Write
Typ e
Com m and
N otes
Load s the cam era configu ration set sp ecified by the User Set Selector featu re, from the
cam era and m akes it active. Disabled w hen
flatfieldCorrectionM ode
=
Calibration
.