N ame
outputLinePulseD elay
Disp lay N am e
Output Line Pulse D elay
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Beginner
Access
Read -Write
Typ e
Integer
Units
µs
Valu es
0 to 8388608 µs
N otes
Sets the d elay before the ou tp u t line p u lse d u ration is ou tp u t.
N ote:
LineM ode feature must be set to
Output
and
outputLineSource
is not equ al to
Off or
SoftwareControlled
.
N ame
outputLinePulseD uration
Disp lay N am e
Output Line Pulse D uration
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Beginner
Access
Read -Write
Typ e
Integer
Units
µs
Valu es
0 to 8388608 µs
N otes
Sets the d u ration of the ou tp u t p u lse.
N ote:
LineM ode feature must be set to
Output
and
outputLineSource
is not equ al to
Off or
SoftwareControlled
.
N ame
outputLineSoftw areLatchControl
Disp lay N am e
Output Line Softw are Latch Control
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Beginner
Access
Read -Write
Typ e
Enu m eration
Valu es
Off –
changes to the ou tp u t line valu e are ap p lied im m ed iately.
Latch –
changes to the ou tp u t line valu e are ap p lied w hen the Ou tp u t Line Softw are
Com m and is triggered .
N otes
The softw are latch allow s the u ser to set m ore than 1 ou tp u t sim u ltaneou sly
OutputLine
that are cu rrently in Softw are Latch control w ill only set w ith the valu e in
OutputLineV alue
w ith the
outputLineSoftwareCmd
featu re.
N ame
outputLineValue
Disp lay N am e
Output LineValue
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Beginner
Access
Read -Write
Typ e
Enu m eration
Valu es
A ctive
- Sets the Ou tp u t circu it to close.
Inactive
- Sets the Ou tp u t circu it to op en.
N otes
Selects the state of the ou tp u t on the selected line. The Valu e w ill be ap p lied im m ed iately if
the
outputLineSoftwareLatchControl
featu re is equ al to OFF.
The Valu e w ill be ap p lied w hen the
outputLineSoftwareCmd
featu re is set if the
outputLineSoftwareLatchControl
featu re is equ al to LATCH .
N ote:
LineM ode feature must be set to
Output
and
outputLineSource
is set
SoftwareControlled
.