PL-101 Specifications
The PL-101 module offers additional isolation for the BOA2 camera and simplifies
wiring at the control panel. The PL-101 is connected to the camera through a single
M12 cordset.
The I/O and RS-232 connections of BOA2 are available through the Pl-101.
Specification for these signals are as follows:
Specification
Definition
Voltage
Load
24 V maximum
Current
GPO[0:1]
200 mA max @ 20°C
Protection
Fuse
PTC fuses to 200 mA at 20°C or 150 mA at 70°C
Common
ICMN/OCMN
PWR or GND as wired on respective OPTOs
Switch Time
GPO[0:1]
800 Microseconds (ON or OFF, includes camera switch time)
PL-101 Connections
I/O connection to
BOA2
Manual Trigger for
debugging
Control panel I/O
connections
9 pin DSUB for
serial connection
O
U
T
0
RS-232
M12
O
U
T
1
O
U
T
2
O
C
M
N
I
N
0
I
N
1
I
N
2
I
C
M
N
P
W
R
G
N
D
E
R
H
TRIGGER
I
0
I
1
I
2
O
0
O
1
O
2
INPUTS
OUTPUTS
Version 4.3; 2017-11-20
33
BOA2-XA Installation