5
EN_ARBITRARY_LH
= 1
Ł
Switch on line hopping via LUT
0
6
EN_GLOBAL_RESET
= 1
Ł
switch on global reset of the sensors
1
7
EN_MCLK
= 1
Ł
activate external pixel clock
0
Table 16: Mode Register 3 (Register address REGADDR = 13D = 0DH)
Register address 13 - MODE3_REG
Bit Name
Description
Default
0
EN_EXPOSURE_PW
External integration control (Pulse-
Width-Modulation) with EXPOSURE
signal
0
1
EN_EXPOSURE_FT
External integration control by edge
triggering EXSYNC and EXPOSURE,
integration begins on positive edge of
EXSYNC signal, integration ends on
positive edge of EXPOSURE signal
0
2
EN_SYNC_EXPOSURE
External triggering and integration
control by EXPOSURE signal,
integration begins on positive edge of
EXPOSURE signal and EXSYNC is on,
integration ends on negative edge of
EXPOSURE Signal
0
3
POLARITY_SYNC_EXPOSURE
= 1
Ł
SYNC_EXPOSURE active HIGH
i.e. rising edge EXSYNC Signal =
EXSYNC and EXPOSURE on, falling
edge EXSYNC Signal = Exposure off
0
4
EN_SHUTTER
= 1
Ł
SHUTTER Signal active, for
CameraLink standard set 0
Ł
Ł
Ł
Ł
DVAL =
1
5
EN_PRELOAD
= 1
Ł
Enable line preload
1
6
EN_LINE_RESET
= 1
Ł
Enable line reset at the middle of
a line
0
7
Not Used
0
0
Table 17: Mode Register 4 (Register address REGADDR = 14D = 0EH)
Register address 14 - MODE4_REG
Bit
Name
Description
Default
0
SLAVE_ACTIVE
= 1
Ł
Enable asynchronous serial
communications interface to ADC module
0
1 to 7
Not used
-
0
Registers 15-17 (exposure time)
The exposure time is stored in three (15 – 17) 8 bit registers (24 bits total).
The exposure time is set in increments of the pixel clock. For the 1M28, each increment is
35 ns. For the 1M75, each increment is 50 ns. The final exposure time can be calculated by
changing the stored binary value to a decimal value and multiplying by the time of the
appropriate increment for your camera.
Summary of Contents for 1M28-SA
Page 4: ...4 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Page 18: ...18 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Page 28: ...28 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Page 44: ...44 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Page 48: ...48 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Page 52: ...52 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...